Basic Description of Controls
General
THE CONTROL OFFERS :
• 20 programmable programs (including 9 pre-programmed
ones) kept in memory
• Each Program can be build in 5 steps
• Setting the machine options and configuration
• Multiple languages can be selected (one at a time)
IN OPERATION THE FOLLOWING DATA IS DISPLAYED :
• The selected program
• The active step
• The remaining program time
• The sequence function
• Indication of wait
• The temperature can be viewed
• Diagnostic messages
THE OPERATION MENU :
• A program can be manually Shortened, Extended, Stopped.
• Service information
• Special function buttons to create simple dryer program
THE HARDWARE AND SOFTWARE OF THE FLEX CON-
TROL DRYER COMPUTER
• Easy operation by a comprehensive keypad
• The hardware contains 1 electronic board
• The FLEX CONTROL board with Alphanumerical LCD dis-
play
• The dryer control software is implemented in a Flash Memory
that can be easily replaced
• The Dryer Programs are kept in EEPROM memory ( non-vol-
atile memory)
Specific Information
The PROGRAM Menu is designated for :
• The creation and implementation of a new dryer program step
by step.
• Editing a dryer program step by step.
• Adding, inserting and deleting steps in the dryer program.
• Copying a dryer program.
• Inspecting the dryer program by the view function.
The CONFIGURATION Menu is designated for :
• The selection of the machine type.
• Loading the default factory settings for the CONFIGURA-
TION and INITIALIZATION menu.
• Erasing all the programmed dryer programs (reset Dryer pro-
gram EEPROM memory).
• Loading the standard dryer programs.
• The selection if the temperature must be displayed in degrees
Celsius or degrees Fahrenheit.
• The selection of the Brightness of the display.
The INITIALIZATION Menu is designated for :
• The selection of the displayed Language.
• Programming the Service due value.
• The selection of the Buzzer time interval.
• The selection of the Advance function.
• Programming the Default Motor On and Off times for revers-
ing motor action.
The SERVICE Menu is designated for :
• The inspection of the error messages log register and the list
with statistics.
• The inspection of the functionality of the electric input sig-
nals.
• Resetting the cycle counter.
The DIAGNOSTIC Menu is designated for starting up a diagnos-
tic program.