64
505872
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
(3) Remove screw holding power cord ground
wire to terminal block bracket.
NOTE: Reconnect ground wire into same hole in
bracket when reinstalling power cord.
(4) Disconnect molex plug and remove power
cord from rear of dryer cabinet.
61. CABINET
a. On Card Reader Models: Remove panel lock (if
present. Refer to Figure 7.
NOTE: Several turns of the key may be required to
remove Panel Lock.
b. Remove two control panel attaching screws and
lift assembly off cabinet top. Refer to Figure 7.
c. Disconnect all wires to temperature switch,
PUSH-TO-START switch and INDICATOR
LIGHT and remove ground clip and screw
holding ground wire to cabinet top and control
panel. Refer to Figure 7.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
d. Metered models:
(1) Insert key in service door lock on top of
meter case and unlock door. Refer to
Figure 10.
(2) Lift rear end of service door approximately
45° off meter case to disengage notched
tabs with internal rib at top of meter case.
Refer to Figure 10.
NOTE: When reinstalling service door and
accumulator, front end of door must be inserted at
about a 45° angle in order to engage notched tabs
with internal rib at top of meter case.
(3) Disconnect accumulator wires at
connectors. Refer to Figure 10.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
(4) Remove hex head ground screw holding
green ground wire to accumulator
mounting bracket. Refer to Figure 10.
(5) Remove one hex head cap screw (right rear
corner) holding meter case to cabinet top.
Refer to Figure 12.
e. Non-metered models:
(1) Remove four screws and lockwasher
holding timer and plate to timer case. Refer
to Figure 12.
NOTE: When reinstalling timer plate, lockwasher
must be between head of screw and plate.
(2) Pull timer and plate out of timer case as far
as wires will permit. Refer to Figure 8.
(3) Remove screw, lockwasher and locknut
holding ground wires to timer, Figure 8.
(4) Disconnect wires from timer. Refer to
NOTE: Refer to appropriate wiring diagram when
rewiring timer.
f. Remove two screws from bottom edge of front
panel. Refer to Figure 13.
g. Swing bottom of panel away from dryer to
disengage hold-down clips and guide lugs from
cabinet top. Refer to Figure 13.
h. Disconnect wires from door switch. Refer to
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
i. Remove two cabinet top hold-down screws.
j. Lift cabinet top to a vertical position by hinging
it on the rear hold-down brackets. Refer to
Figure 15.
NOTE: Cabinet top may be raised and hinged on
the rear hold-down brackets or supported against
wall behind dryer while servicing.
k. Carefully withdraw wire harness through hole
in cabinet top and lift the cabinet top assembly
off the hold-down brackets and set to the side.
Refer to Figure 15.