10
505872
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3. MOTOR RUNS BUT CYLINDER DOES NOT TURN
4. MOTOR DOES NOT STOP
5. MOTOR STARTS WHEN DOOR IS CLOSED
POSSIBLE CAUSE
TO CORRECT
Motor drive pulley loose.
• Tighten setscrew, Figure 29.
Broken cylinder belt.
• Replace belt.
Cylinder belt is upside down or twisted.
• Install properly.
Clothes cylinder is binding.
• Check cylinder for binding and “out of round” condition.
• Check front and rear bulkheads for warping.
• Check cylinder rollers for binding.
• Check cylinder seals and glides for wear or damage.
Broken or disconnected idler lever spring.
• Replace or reconnect spring. Refer to Figure 29.
POSSIBLE CAUSE
TO CORRECT
Inoperative door switch.
• Test switch and replace if inoperative.
Inoperative timer – nonmetered models.
• Test timer and replace if inoperative.
Inoperative accumulator—metered models.
• Test accumulator and replace if inoperative.
Incorrect wiring.
• Refer to appropriate wiring diagram.
POSSIBLE CAUSE
TO CORRECT
Inoperative start switch.
• Test switch and replace if inoperative.