52
505872
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
50. FRONT AIR DUCT
a. Remove two screws from bottom edge of front
panel. Refer to Figure 13.
b. Swing bottom of panel away from dryer to
disengage hold-down clips and guide lugs from
cabinet top. Refer to Figure 13.
c. Disconnect wires from door switch. Refer to
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
d. Remove two screws from lint filter and lift filter
out of bulkhead. Refer to Figure 16.
NOTE: When installing lint filter, be sure to install
the filter with the words “FRONT” facing the front
of the dryer.
e. Remove four screws holding duct to front
bulkhead and remove air duct. Refer to
Figure 25.
NOTE: When reassembling, be sure felt seal on
exhaust fan cover makes air tight seal on flange of
duct. Refer to Figure 24.
51. EXHAUST DUCT
a. Disconnect electric power, vent (and gas line if
necessary) and move unit to gain access to rear
of dryer.
b. Remove screw holding bracket on exhaust duct
to rear of cabinet. Refer to Figure 26.
c. Pull duct out through rear of cabinet.
Figure 25
Figure 26
DR005-SV-1
CABINET
ATTACHING SCREWS
HEX
HEAD
SCREWS
SLOT
AIR
DUCT
HEX
HEAD
SCREWS
PHILLIPS
HEAD
SCREWS
HEX HEAD
SCREWS
DR042-SV-1
EXHAUST
DUCT
SCREW
GROUND
SCREW
ACCESS
PLATE
MOUNTING BRACKET
ATTACHING SCREWS