31. TIMER CASE
a. Remove two control panel attaching screws and
lift assembly off cabinet top. Refer to Figure 7.
b. Disconnect all wires to temperature switch,
PUSH-TO-START switch and INDICATOR
LIGHT and remove ground clip and screw
holding ground wire to cabinet top and control
panel. Refer to Figure 5.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
c. Remove four screws and lockwasher holding
timer and plate to timer case. Refer to Figure 8.
NOTE: When reinstalling timer plate, lockwasher
must be between head of screw and plate.
d. Pull timer and plate out of timer case as far as
wires will permit. Refer to Figure 8.
e. Remove screw, lockwasher and locknut
holding ground wires to timer. Refer to
Figure 8.
f. Disconnect wires from timer. Refer to Figure 8.
NOTE: Refer to appropriate wiring diagram when
rewiring timer.
g. Remove cap screw, lockwashers and nut
holding timer case to control hood. Refer to
Figure 7.
h. Remove two screws from bottom edge of the
front panel. Refer to Figure 13.
i. Swing bottom of panel away from dryer to
disengage hold-down clips and guide lugs from
cabinet top. Refer to Figure 13.
j. Disconnect wires from door switch. Refer to
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
k. Remove two cabinet top hold-down screws.
l. Lift cabinet top to a vertical position by hinging
it on the rear hold-down brackets. Refer to
Figure 15.
NOTE: Cabinet top may be raised and hinged on
the rear hold-down brackets or supported against
wall behind dryer while servicing.
m. Carefully withdraw wire harness through hole
in cabinet top and lift the entire cabinet top
assembly off the hold-down brackets. Refer to
Figure 15.
n. Lay the cabinet top assembly flat and remove
two carriage bolts, washers, lockwashers and
nuts holding front of timer case to cabinet top.
Refer to Figure 8.
o. Remove screw holding rear of case to cabinet
top and remove case. Refer to Figure 8.
32. CABINET TOP – NON-METERED MODELS
a. Remove two control panel attaching screws and
lift assembly off cabinet top. Refer to Figure 7.
b. Disconnect all wires to temperature switch,
PUSH-TO-START switch and INDICATOR
LIHT and remove ground clip and screw
holding ground wire to cabinet top and control
panel. Refer to Figure 5.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
c. Remove four screws and lockwasher holding
timer and plate to timer case. Refer to Figure 8.
NOTE: When reinstalling timer plate, lockwasher
must be between head of screw and plate.
d. Pull timer and plate out of timer case as far as
wires will permit. Refer to Figure 8.
e. Remove screw, lockwasher and locknut
holding ground wires to timer. Refer to
Figure 8.
f. Disconnect wires from timer. Refer to Figure 8.
NOTE: Refer to appropriate wiring diagram when
rewiring timer.
g. Remove cap screw, lockwashers and nut
holding timer case to control hood. Refer to
Figure 7.