Rockwell Automation Publication 2080-UM002K-EN-E - March 2019
23
About Your Controller
Chapter
2
WARNING:
When used in a Class I, Division 2, hazardous location, this equipment must be mounted in a
suitable enclosure with proper wiring method that complies with the governing electrical codes.
WARNING:
If you connect or disconnect the serial cable with power applied to this module or the serial
device on the other end of the cable, an electrical arc can occur. This could cause an explosion in hazardous
location installations. Be sure that power is removed or the area is nonhazardous before proceeding.
WARNING:
The local programming terminal port is intended for temporary use only and must not be
connected or disconnected unless the area is assured to be nonhazardous.
WARNING:
The USB port is intended for temporary local programming purposes only and not intended for
permanent connection.If you connect or disconnect the USB cable with power applied to this module or any
device on the USB network, an electrical arc can occur. This could cause an explosion in hazardous location
installations. Be sure that power is removed or the area is nonhazardous before proceeding.
The USB port is a nonincendive field wiring connection for Class I, Division2 Groups A, B, C and D.
WARNING:
Exposure to some chemicals may degrade the sealing properties of materials used in the
Relays. It is recommended that the User periodically inspect these devices for any degradation of
properties and replace the module if degradation is found.
WARNING:
If you insert or remove the plug-in module while backplane power is on, an electrical arc can
occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or
the area is nonhazardous before proceeding.
WARNING:
When you connect or disconnect the Removable Terminal Block (RTB) with field side power
applied, an electrical arc can occur. This could cause an explosion in hazardous location installations.
WARNING:
Be sure that power is removed or the area is nonhazardous before proceeding.
ATTENTION:
To comply with the CE Low Voltage Directive (LVD), this equipment must be powered from a
source compliant with the following: Safety Extra Low Voltage (SELV) or Protected Extra Low Voltage (PELV).
ATTENTION:
To comply with UL restrictions, this equipment must be powered from a Class 2 source.
ATTENTION:
Be careful when stripping wires. Wire fragments that fall into the controller could cause
damage. Once wiring is complete, make sure the controller is free of all metal fragments.
ATTENTION:
Do not remove the protective debris strips until after the controller and all other equipment in
the panel near the module are mounted and wired. Remove strips before operating the controller. Failure to
remove strips before operating can cause overheating.
ATTENTION:
Electrostatic discharge can damage semiconductor devices inside the module. Do not touch
the connector pins or other sensitive areas.
ATTENTION:
The USB and serial cables are not to exceed 3.0 m (9.84 ft).
ATTENTION:
Do not wire more than 2 conductors on any single terminal.
ATTENTION:
Do not remove the Removable Terminal Block (RTB) until power is removed.
Summary of Contents for Micro830
Page 6: ...vi Rockwell Automation Publication 2080 UM002K EN E March 2019 Preface Notes ...
Page 273: ...Rockwell Automation Publication 2080 UM002K EN E March 2019 259 Quickstarts Appendix C ...
Page 300: ...286 Rockwell Automation Publication 2080 UM002K EN E March 2019 Appendix C Quickstarts Notes ...
Page 352: ...Rockwell Automation Publication 2080 UM002K EN E March 2019 338 Index Notes ...
Page 353: ...Rockwell Automation Publication 2080 UM002K EN E March 2019 339 ...