Publication 1756-UM001G-EN-P - January 2007
96
Develop Motion Applications
4.
From the Cycle Time pull-down menu, choose the cycle time.
5.
Click OK.
Baud Rate
of Drive
Number of Drives
on Ring
Type of Drive
Cycle Time
4 MB
1 or 2
Kinetix 6000
0.5 ms
3 or 4
1 ms
5…8
2 ms
9…16
Not possible. You must
have 2 motion modules.
1…4
Not Kinetix 6000
1 ms
5…8
2 ms
9…16
Not possible. You must
have 2 motion modules.
8 MB
1…4
Kinetix 6000
0.5 ms
5…8
1 ms
9…16
2 ms
1…8
Not Kinetix 6000
1 ms
9…16
2 ms