Communicate over Networks
6.
From the Protocol pull-down menu, choose DF1 Point-to-Point.
7.
Specify DF1 system protocol settings.
8.
Click OK.
Additional Resources
For additional information, consult these publications:
•
Logix5000 Controllers General Instructions Reference Manual,
publication 1756-RM003
•
SCADA System Application Guide, publication AG-UM008.
Communicate with ASCII Devices
When you configure the serial port for user mode, you can use it to:
•
read ASCII characters from a weigh scale module or bar code
reader.
•
send and receive messages from an ASCII-triggered device, such
as a MessageView terminal.
To communicate with ASCII devices, perform this procedure.
1.
In the Controller Organizer of RSLogix 5000 programming
software, right-click your controller and select Properties.
Connection from the Controller’s Serial Port to the ASCII Device