Fleet Shower Room Assembly Instructions

 

 
The base, sacrificial runners, drain pan, floor-grating and related parts are 
shipped from the factory as a sub-assembly. The following instructions are 
to be used for reference purposes should any of these components need to 
be replaced. 
 
STEP 1. 

BASE AND DRAIN PAN ASSEMBLY:  

Refer to figure 3. Thread four 5/16"-18x2”, PC-
000167, stainless steel studs into the 
threaded inserts on the underside of the 
drain pan. 

CAUTION: screw the studs in 

by hand. Do not over-tighten, which 
could rupture the drain pan or 
strip the threads in the insert. 

 
Be sure to have a clean work 
surface that will not scratch the 
top surface of the drain pan. Turn 
the drain pan upside down with 
the studs pointing up. Turn the 
base upside down and place the open 
rectangular area of the base with four slots in it 
onto the four studs in the drain pan. Shift the base 
around until the studs on the bottom of the drain pan go into the slots 
provided in the base. Align the studs and slots so that they are 
centred. Install a 7/16 flat washer PC-000126, a 5/16” flat washer PC-
000168 and then thread a 5/16” nylon lock nut PC-000173 on the end 
of each stud. Stand the base and drain pan upright. Add the small 
round flat shower drain strainer to the hole in the top centre of the 
drain pan by slightly bending the tabs outwards and then insert it into 
the hole. 

 
STEP 2. 

DRAIN PAN AND FLOOR GRATING ASSEMBLY: 

Refer to figure 4. The floor grating is fastened to the drain pan 
with four, hold-down clips SH1-0010 and four  
#10 x 1 ½" oval head, self-tapping screws PC-
000158. The clips slide between the 
vertical legs of the "T" extrusions as 
shown and the screws are driven 
in with a drill and crosshead drill 
bit.  

 
 
 
 

 

Figure 3 

Figure 4 

Summary of Contents for Fleet Shower SH1 Series

Page 1: ...ontact us above or E mail us customerservice allsafetyproducts com NOTE All Safety Products reserves the right to make changes without prior notice Exterior Height 91 0 in 231 0 cm Interior Height 83...

Page 2: ...l hygiene when permanent facilities are destroyed due to disasters such as earthquakes tornadoes typhoon s hurricanes fires and flooding Installation requires a pressurised fresh water source and conn...

Page 3: ...read through the entire assembly instructions prior to proceeding We strongly suggest that these shower rooms as with all portable structures be transported and handled with care Dropping the shower r...

Page 4: ...999 Page 4 of 17 Fleet Shower Room Exploded Parts Drawing NOTE ITEM NUMBERS LISTED IN THE BILL OF MATERIALS WITH AN ALPHABETICAL SUFFIX ARE NOT SHOWN HOWEVER THEY ARE USED WITH THE NUMBER BEFORE IT Fi...

Page 5: ...ong 1 14 PC 100531 Coupler Fernco 2 w clamps 2 15 PC 100535 Pipe 2 PVC sched 40 x 3 long 1 16 PC 100533 Elbow bend 90 vent street 2 17 PC 100532 Elbow bend 90 street 1 ITEM PART DESCRIPTION REQ 18 SG1...

Page 6: ...1 1 4 Fender Washer PC 000158 10 x 1 1 2 Oval Head Self Tapping Phillips Head Screw PC 000160 5 16 18 x 3 4 Hex Head Bolt PC 000161 5 16 Flat Washer PC 000162 10 x 1 3 4 Self Tapping Spanner Screw PC...

Page 7: ...n and place the open rectangular area of the base with four slots in it onto the four studs in the drain pan Shift the base around until the studs on the bottom of the drain pan go into the slots prov...

Page 8: ...end of the 2 flexible rubber coupling and clamp in place Next clamp another 2 flexible coupling onto the nipple end of the trap assembly Then push the 2 x 10 piece of pipe through the hole at the rea...

Page 9: ...rain pan and hold in place with a 3 8 staple Slightly stretch the seal around the corner of the drain pan and put another staple approximately 4 from the first staple Continue to slightly stretch and...

Page 10: ...awls into the centre holes Be sure to put the rear panels into the correct slots of the extrusions STEP 7 WALL PANELS AND REAR EXTRUSIONS SUB ASSEMBLY Remove an awl from one edge of the rear wall and...

Page 11: ...n the inside top surface of the side wall panel HINT hold the screens in place with two small strips of masking tape Install the other fly screen Position the roof over the unit pushing it all the way...

Page 12: ...0323 straight fitting and thread it into the 1 2 FPT nipple on the shower tower assembly CAUTION be sure to tape only the threads Do not allow any tape to get into the plumbing system To determine the...

Page 13: ...on the outside Drill a 13 64 hole using the fresh water hose connector as a guide through the right side flange of the plastic cover and rivet from the inside using a PC 000102 rivet and PC 000106 ba...

Page 14: ...3 over and 1 2 up from this hole and rivet in place Drill another hole on the underside of the shelf one half way across the diagonal corner and rivet in place Hold the inside lip of the shelf against...

Page 15: ...the way to the left and in the neutral position when pointing up This is important During normal use turn the lock to the neutral position and remove the key This will allow the slide latch to move in...

Page 16: ...sed to prevent persons from inadvertently moving the slide latch to the In use position when leaving the shower room Insert 1 3 4 self tapping spanner screws PC 000162 in each of the four holes and ti...

Page 17: ...D ABRASIONS MAYBE LIGHTLY SANDED OR SCRUBBED WITH A MILD ABRASIVE CLEANER such as Soft N Scrub THAT CONTAINS CALCIUM CARBONATE HYPOCHLORATE BLEACH AND DETERGENTS BE SURE TO FOLLOW THE CLEANING PRODUCT...

Reviews: