All Safety Products Fleet Shower SH1 Series Manual Download Page 13

Figure 13 

April 1999 

                         Page 13 of  17 

Fleet Shower Model Assembly Instructions

 

 

STEP 13.  FRESH WATER INLET PLUMBING (cont.). 

 
Drill a 1 1/8" diameter hole. Using the fresh water hose connector as a 
drill guide, position it in the hole on the outside of the rear panel and 
drill two 13/64" holes. It's best to drill the holes on a horizontal plane 
for a good visual appearance. Rivet the hole closest to the shower 
tower from the outside using a PC-000102 rivet PC-000106 back-up 
washer the other hole is riveted when the plastic housing is installed. 
Apply Teflon tape to the threaded end of the elbow and thread it to the 
1/2" FPT on the fresh water hose connector. Next slide two #12 clamps 
on to the 3/4"ID x 3 1/2" long hose and force both hose ends over the 
hose barbs of the straight and elbow fittings and tighten the clamps. 
 
Position the plastic cover over the fresh water plumbing components.  
Hold the cover level and drill four 13/64" holes, one in each of the 
corners of the flange of the housing as shown in figure 12. Rivet from 
the inside using PC-000102 rivets and PC-000106 washers on the 
outside. Drill a 13/64" hole using the fresh water hose connector as a 
guide through the right side flange of the plastic cover and rivet from 
the inside using a PC-000102 rivet and PC-000106 back-up washer.  

 
STEP 14.  CLOTHES HOOKS, SHOWER CURTAIN AND HANGING ROD: 

There are two clothes hooks located on the 
inside left and right diagonal corners. A 
hook is shown on the left side in figure 13. 
There is a rib towards the top on the 
diagonal corner. Using the hook as a drill 
guide, hold it up against this rib, towards 
the door and drill two 13/64" diameter 
holes. Fasten in place from the outside with 
two PC-000102 rivets and PC-000106 back-
up washers on the inside. Install the other 
hook on the inside right corner. 
 
The shower curtain rod is a three-piece 
assembly consisting of two flanges and 
one 1" diameter x 39 ¾" long tube. Position 
the flanges on the long tube. Use the 
flanges as a drill guide and drill two 13/64" 
diameter holes. Make these holes on a 
vertical plane, top to bottom, for more strength. Rivet in place from the 
inside using PC-000102 rivets and PC-000106 back-up washers on the 
outside. Make sure the long tube is level. Drill and rivet the other 
flange in place. Add the shower curtain hooks to the shower curtain; 
slip them over the curtain rod and snap in place. 

Summary of Contents for Fleet Shower SH1 Series

Page 1: ...ontact us above or E mail us customerservice allsafetyproducts com NOTE All Safety Products reserves the right to make changes without prior notice Exterior Height 91 0 in 231 0 cm Interior Height 83...

Page 2: ...l hygiene when permanent facilities are destroyed due to disasters such as earthquakes tornadoes typhoon s hurricanes fires and flooding Installation requires a pressurised fresh water source and conn...

Page 3: ...read through the entire assembly instructions prior to proceeding We strongly suggest that these shower rooms as with all portable structures be transported and handled with care Dropping the shower r...

Page 4: ...999 Page 4 of 17 Fleet Shower Room Exploded Parts Drawing NOTE ITEM NUMBERS LISTED IN THE BILL OF MATERIALS WITH AN ALPHABETICAL SUFFIX ARE NOT SHOWN HOWEVER THEY ARE USED WITH THE NUMBER BEFORE IT Fi...

Page 5: ...ong 1 14 PC 100531 Coupler Fernco 2 w clamps 2 15 PC 100535 Pipe 2 PVC sched 40 x 3 long 1 16 PC 100533 Elbow bend 90 vent street 2 17 PC 100532 Elbow bend 90 street 1 ITEM PART DESCRIPTION REQ 18 SG1...

Page 6: ...1 1 4 Fender Washer PC 000158 10 x 1 1 2 Oval Head Self Tapping Phillips Head Screw PC 000160 5 16 18 x 3 4 Hex Head Bolt PC 000161 5 16 Flat Washer PC 000162 10 x 1 3 4 Self Tapping Spanner Screw PC...

Page 7: ...n and place the open rectangular area of the base with four slots in it onto the four studs in the drain pan Shift the base around until the studs on the bottom of the drain pan go into the slots prov...

Page 8: ...end of the 2 flexible rubber coupling and clamp in place Next clamp another 2 flexible coupling onto the nipple end of the trap assembly Then push the 2 x 10 piece of pipe through the hole at the rea...

Page 9: ...rain pan and hold in place with a 3 8 staple Slightly stretch the seal around the corner of the drain pan and put another staple approximately 4 from the first staple Continue to slightly stretch and...

Page 10: ...awls into the centre holes Be sure to put the rear panels into the correct slots of the extrusions STEP 7 WALL PANELS AND REAR EXTRUSIONS SUB ASSEMBLY Remove an awl from one edge of the rear wall and...

Page 11: ...n the inside top surface of the side wall panel HINT hold the screens in place with two small strips of masking tape Install the other fly screen Position the roof over the unit pushing it all the way...

Page 12: ...0323 straight fitting and thread it into the 1 2 FPT nipple on the shower tower assembly CAUTION be sure to tape only the threads Do not allow any tape to get into the plumbing system To determine the...

Page 13: ...on the outside Drill a 13 64 hole using the fresh water hose connector as a guide through the right side flange of the plastic cover and rivet from the inside using a PC 000102 rivet and PC 000106 ba...

Page 14: ...3 over and 1 2 up from this hole and rivet in place Drill another hole on the underside of the shelf one half way across the diagonal corner and rivet in place Hold the inside lip of the shelf against...

Page 15: ...the way to the left and in the neutral position when pointing up This is important During normal use turn the lock to the neutral position and remove the key This will allow the slide latch to move in...

Page 16: ...sed to prevent persons from inadvertently moving the slide latch to the In use position when leaving the shower room Insert 1 3 4 self tapping spanner screws PC 000162 in each of the four holes and ti...

Page 17: ...D ABRASIONS MAYBE LIGHTLY SANDED OR SCRUBBED WITH A MILD ABRASIVE CLEANER such as Soft N Scrub THAT CONTAINS CALCIUM CARBONATE HYPOCHLORATE BLEACH AND DETERGENTS BE SURE TO FOLLOW THE CLEANING PRODUCT...

Reviews: