All Safety Products Fleet Shower SH1 Series Manual Download Page 2

April 1999 

    Page 2 of  17 

Fleet Shower Model 

GENERAL PRODUCT OVERVIEW

 

 

The 

Fleet Shower Room

 provides a private, personal hygienic bathing 

facility for a variety of rental applications. These include: 

 
RECREATION: campgrounds, parks, residential & municipal 
                          swimming pools, marinas, sporting events and ocean or  
                          lake front hotels  
CONSTRUCTION: work crew clean up from dusty environments such 
                          as building demolition, ground grading and land  
                          preparation, sanitary landfills, roofing and flushing of 
                          hazardous materials  
AGRICULTURE: removal of crop duster chemicals and provides 
                          personal hygiene at migrant farm worker camps 
MUNICIPAL:    fire departments to remove carbon dust and cool down  
                          of fire fighting personnel  
NATURAL DISASTERS: clean and cool-down of crews fighting 
                          forest fires. Provides personal hygiene when permanent 
                          facilities are destroyed due to disasters such as 
                          earthquakes, tornadoes, typhoon's, hurricanes, fires and 
                          flooding 

 
Installation requires a pressurised, fresh water source and connection to a 
sewage disposal system such as municipal wastewater, septic and holding 
tanks.  
 
The fresh water system uses a standard garden hose type connection. The 
showerhead dispenses 2 ½ gallons (9.5 litres) of water per minute. The shower 
is activated by a ball valve. There is a combination faucet and hose bib that can 
be used for cleaning the shower room and as a source of water for other 
purposes. 
 
The grey wastewater plumbing components are 2" schedule 40 PVC fittings 
including a trap to prevent odours from seeping into the shower room from the 
sewage connection, which is at the rear of the shower room. The 2" PVC 
fittings are connected with 2" Fernco® flexible rubber couplings and clamps 
which allow for easy maintenance should the plumbing system become 
clogged or require repair.   

 
 
 
 
 
 
 
 

Summary of Contents for Fleet Shower SH1 Series

Page 1: ...ontact us above or E mail us customerservice allsafetyproducts com NOTE All Safety Products reserves the right to make changes without prior notice Exterior Height 91 0 in 231 0 cm Interior Height 83...

Page 2: ...l hygiene when permanent facilities are destroyed due to disasters such as earthquakes tornadoes typhoon s hurricanes fires and flooding Installation requires a pressurised fresh water source and conn...

Page 3: ...read through the entire assembly instructions prior to proceeding We strongly suggest that these shower rooms as with all portable structures be transported and handled with care Dropping the shower r...

Page 4: ...999 Page 4 of 17 Fleet Shower Room Exploded Parts Drawing NOTE ITEM NUMBERS LISTED IN THE BILL OF MATERIALS WITH AN ALPHABETICAL SUFFIX ARE NOT SHOWN HOWEVER THEY ARE USED WITH THE NUMBER BEFORE IT Fi...

Page 5: ...ong 1 14 PC 100531 Coupler Fernco 2 w clamps 2 15 PC 100535 Pipe 2 PVC sched 40 x 3 long 1 16 PC 100533 Elbow bend 90 vent street 2 17 PC 100532 Elbow bend 90 street 1 ITEM PART DESCRIPTION REQ 18 SG1...

Page 6: ...1 1 4 Fender Washer PC 000158 10 x 1 1 2 Oval Head Self Tapping Phillips Head Screw PC 000160 5 16 18 x 3 4 Hex Head Bolt PC 000161 5 16 Flat Washer PC 000162 10 x 1 3 4 Self Tapping Spanner Screw PC...

Page 7: ...n and place the open rectangular area of the base with four slots in it onto the four studs in the drain pan Shift the base around until the studs on the bottom of the drain pan go into the slots prov...

Page 8: ...end of the 2 flexible rubber coupling and clamp in place Next clamp another 2 flexible coupling onto the nipple end of the trap assembly Then push the 2 x 10 piece of pipe through the hole at the rea...

Page 9: ...rain pan and hold in place with a 3 8 staple Slightly stretch the seal around the corner of the drain pan and put another staple approximately 4 from the first staple Continue to slightly stretch and...

Page 10: ...awls into the centre holes Be sure to put the rear panels into the correct slots of the extrusions STEP 7 WALL PANELS AND REAR EXTRUSIONS SUB ASSEMBLY Remove an awl from one edge of the rear wall and...

Page 11: ...n the inside top surface of the side wall panel HINT hold the screens in place with two small strips of masking tape Install the other fly screen Position the roof over the unit pushing it all the way...

Page 12: ...0323 straight fitting and thread it into the 1 2 FPT nipple on the shower tower assembly CAUTION be sure to tape only the threads Do not allow any tape to get into the plumbing system To determine the...

Page 13: ...on the outside Drill a 13 64 hole using the fresh water hose connector as a guide through the right side flange of the plastic cover and rivet from the inside using a PC 000102 rivet and PC 000106 ba...

Page 14: ...3 over and 1 2 up from this hole and rivet in place Drill another hole on the underside of the shelf one half way across the diagonal corner and rivet in place Hold the inside lip of the shelf against...

Page 15: ...the way to the left and in the neutral position when pointing up This is important During normal use turn the lock to the neutral position and remove the key This will allow the slide latch to move in...

Page 16: ...sed to prevent persons from inadvertently moving the slide latch to the In use position when leaving the shower room Insert 1 3 4 self tapping spanner screws PC 000162 in each of the four holes and ti...

Page 17: ...D ABRASIONS MAYBE LIGHTLY SANDED OR SCRUBBED WITH A MILD ABRASIVE CLEANER such as Soft N Scrub THAT CONTAINS CALCIUM CARBONATE HYPOCHLORATE BLEACH AND DETERGENTS BE SURE TO FOLLOW THE CLEANING PRODUCT...

Reviews: