The Setup Cutoff and Delay After Fill screen provides access to selections to control a cutoff
device (if used), and a variable delay after fill to coordinate the auger filler with operation of
other, external, equipment.
Cutoff Control
Product cutoff devices that can be installed at the funnel of the filler can be controlled using
these selections. The following types of cutoff control are available.
None
No cutoff control required.
By Time
Specifies a period of time for the cutoff to open and
close. The actual time is specified in the OPEN
TIME and CLOSE TIME entries.
Limit Switch
Specifies a period of time to delay the closing of the
cutoff. The limit switch determines cutoff opening
and filling. The opening time is not selectable in this
mode.
Open Time
Specifies the amount of time that it takes to fully
open the cutoff, prior to the start of the fill. Entries
can be made in this window only if cutoff control
has been selected as “Time.”
Close Time
Specifies the amount of time (delay) that it takes to
fully close the cutoff, after the fill is completed, can
be specified. Entries can be made in this window
when cutoff control has been selected as either
“Time” or “Limit Switch.”
Types of cutoff devices used will vary with design, product characteristics, and other acces-
sories used at the filler.
This selection is available from the Setup Cutoff and Delay After Fill screen.
Factory Settings
Cutoff Control: None
Open Time: 0.00
Close Time: 0.00
Valid Entries
Cutoff Control: By Time, Limit Switch, None
Open Time: 0.0-99.99
Close Time: 0.0-99.99
Model B-SV-600 Touch Screen Control Panel Users Manual
26
AFI Publication 1240410
•
Issue: 1
•
April 2010
Setup Cutoff and
Delay After Fill