![ALL-FILL B-SV-600 User Manual Download Page 28](http://html1.mh-extra.com/html/all-fill/b-sv-600/b-sv-600_user-manual_2897927028.webp)
Auger Speed
Selects the final operating speed of the servo fill motor. Selections from 50 to 1500 rpm are
available. Speed settings will vary according to amount of fill, desired accuracy levels, as
well as production rates.
Factory Setting:
0 rpm
Valid Entries:
50-1200 rpm
Agitator Control
The on/off control and duration of product agitation can be controlled with this selection.
Selections are available for continuous agitation, agitation during filling only, and no agita-
tion.
Operation of agitation will depend on product type, environmental factors, and specific prod-
uct characteristics.
This selection is available from the Setup Auger and Agitator menu.
Factory Setting:
None
Valid Entries:
With Fill, Continuous, None
Agitation Off Delay
This selection momentarily delays turning agitation off to accommodate high cycle rates and
operation with other equipment.
This selection is available from the Setup Auger and Agitator menu.
Factory Setting:
0.00
Valid Entries:
0.0-99.99