This selection is available from the Setup Target Weight menu.
Factory Setting:
None
Valid Entries:
Servo, A&D Scale, None
Feedback Sec./Wt.
If Feedback selected as “
Servo
” the Feedback Sec/Wt selection defines the amount of time
that is required to change auger revolutions based on weight value. This value should match
the same value on the weighing equipment.
This selection is available from the Setup Target Weight menu.
Factory Setting:
0.00
Valid Entries:
0.00-9.99
Feedback Samples
If Feedback selected as “
A&D Scale
” the Feedback Samples entry selects the total amount
of weight sampling data collected at the A&D Scale during weighing used in calculation of
feedback adjustment. Generally, greater sampling may achieve greater accuracy, however
adjustment may require several fill cycles to complete.
This selection is available from the Setup Target Weight menu.
Factory Setting:
0
Valid Entries:
0-9999
The Setup Auger and Agitator screen provides access to selections to select how many
auger revolutions are performed during a fill cycle and operation of the slow speed agitator
drive within the hopper of the filler.
Auger Revolutions
This selection defines the amount of product dispensed during a fill cycle. The amount of
product dispensed per revolution is a function of the auger (or pump) size as well as physi-
cal characteristics of the product (i.e., density).
This selection is available from the Setup Auger and Agitator menu.
Factory Setting:
0.00
Valid Entries:
0.50-999.99
Model B-SV-600 Touch Screen Control Panel Users Manual
24
AFI Publication 1240410
•
Issue: 1
•
April 2010
Setup Auger and
Agitator