2.3 Maintenance Tables
2.3.1 W32 Mariner Compressors Maintenance
–
Parts Control Table
Check
Description
Instruction
nr.
Daily
Oil level
01
Leaks
02
Pressure and pressure gauges.
-
Open the manual drain valves and drain the condensate
collected inside the purifier after each filling procedure.
Check if automatic dra
in valves work properly if it’s
automatic drain adapted unit.
Drain the condensate collected inside the water seperators
manually every 7 minutes while the unit is running
Weekly
Intake Filter.
03
V-Belt tension (See the V-belt replacement instruction )
04
Tightness of fastening parts.
05
Cleaning of cylinder fins, intercoolers and after cooler,
flywheel.
06
Electrical current.
07
Cable connection and wiring.
-
Every 500 hours
Safety valves
Note: Check the safety valves every 500 operating hours and
replace them if needed.
08
08-01
Every 1000 hours
Regulating valve
Note: Check the regulating valve every 1000 operating hours
and replace or maintain it if needed.
09
09-01
Check valve
Note: Check the check valve every 1000 operating hours and
replace or maintain it if needed.
10
10-01
Priorıty valve
Note: check the priority valve every 1000 operating hours
and replace or maintain it if needed.
11
11-01
V-belts
Note: Check the V-belts every 1000 operating hours and
replace them if needed.
12
Oil seal
Note: Check the oil seal every 1000 operating hours and
replace them if needed
13
Annually
Purifier
Note: Have the purifier on your unit pressure tested to the
authorized body according to the pressurized equipment test
regulations.