W 3 2 S E R I E S
H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R
43
1.12.6 Bottle Filling
W32 Mariner Models
•
Start the compressor.
•
Close the manual drain valves on the 2nd and 3rd stage water seperators (do not necessarily do it if
the unit is automatic drain controlled.)
•
Read the oil pressure on the oil pressure gauge and make sure that the oil pressure goes upto 4 to 10
Bar.
•
Close the Purifier Manual Drain Valve, if open.
•
Connect and fix the Filling Hose to the bottle as the filling valve is in closed position.
•
Open the filling valve on the filling hose and then the bottle valve when the pressure reaches 150-200
Bar on the pressure gauge on the filling hose.
•
Close the bottle valve first and then the filling valve when the bottle pressure reaches the desired
pressure (max. working pressure.)
•
Air inside the filling hose is automatically released by the filling valve when the filling valve is closed.
•
Disconnect the filling hose connected to the bottle and stop the compressor when you finish the
filling process.
•
Compressor will automatically stop if it’s automatic start/stop controlled.
•
Drain the condensate collected inside the 2nd and 3rd stage water seperators every 7 minutes
manually and at the end of the filling process. It would be drained automatically if the unit has
automatic drain control.
VALVE
WATER SEPERATOR
2nd STAGE
MANUEL DRAIN
VALVE
WATER SEPERATOR
3rd STAGE
MANUEL DRAIN
OIL PRESSURE
GAUGE
FILLING VALVE
BOTTLE VALVE
DELIVERY
PRESSURE GAUGE
OFF
ON
VALVE
MANUEL DRAIN
ON
OFF
BOTTLE VALVE
FILLING VALVE
PRESSURE GAUGE
DELIVERY
MANUAL DRAIN
VALVE
VALVE
MANUEL DRAIN
WATER SEPERATOR
3rd STAGE
MANUEL DRAIN
VALVE
2nd STAGE
WATER SEPERATOR
OIL PRESSURE
GAUGE