W32 Canopy Models
•
Start the compressor.
•
Read the oil pressure on the oil pressure gauge and make sure that the oil pressure goes upto 4 to 10
Bar.
•
Close the Purifier Manual Drain Valve.
•
Connect and fix the Filling Hose to the bottle as the filling valve is in closed position.
•
Wait till the final pressure reads the working presure on the final stage pressure gauge on the control
panel.
•
Open the filling valve on the filling hose and then the bottle valve when the pressure reaches 150-200
Bar on the pressure gauge on the filling hose.
•
Close the bottle valve first and then the filling valve when the bottle pressure reaches the desired
pressure (max. working pressure)
•
Air inside the filling hose is automatically released by the filling valve when the filling valve is closed.
•
Disconnect the filling hose connected to the bottle when you finish the filling process.
•
Compressor will automatically stop since it’s automatic start/stop contro
lled. It would be drained
automatically since the unit has automatic drain control.
OIL PRESSURE
GAUGE
GAUGE
PURIFIER
ON
OFF
VALVE
FILLING
FINAL GAUGE
MANUAL DRAIN
VALVE
VALVE
BOTTLE