TdC 8000 for Equestrian
Page 8
Version:E-00-08-08
Page 8
2.
OPERATING
2.1.
Power Supply
The TdC 8000 has a built in rechargeable-NiCad-battery-pack (4.5 Ah).
Charge the NiCad-battery-pack with the NLG8 or a 12 Volt car-battery. The charging voltage must
be between 11 and 16 Volts. To load the TdC 8000 you need to turn it on.
2.1.1.
Net-Charging-Set NLG8
With the net-charging-device NLG8 you can load the TdC 8000 direct form the mains:
Plug NLG8 at the mains.
Plug NLG8 at the socket „extern. supply“ (19) or „photocell (20, 21 or 22).
Turn TdC 8000 on (switch 26).
The read LED (3) must burn.
The TdC 8000 must be switched on during the charging process (internal charging electronic)
You can load the TdC 8000 also during the normal timing operation.
The charging process with the NLG8 need about 12 hours.
The no-load-voltage is about 15 VDC.
The charging voltage of the NLG8 is about 11.7 VDC
ALGE has two types of NLG8. One is with 230V/50Hz, the other with 115V/60 Hz. The voltage is
printed on the NLG8 case. Please make sure that you use the NLG8 with the correct voltage for
your mains.
Attention: You cannot load the TdC 8000 when switched off!