TdC 8000 for Equestrian
Page 29
Version: E-01-08-08
Page 29
Input: 0015 RT 000055.446< NEW No F1
valid finish
0015 RT 000048.143 DISQU. F2
0015 RT 000063.941
-
You can over write the valid run time with the finish keyboard (15) (manual input of the finish
time).
-
If you want to copy the selected time to another start number press <F1> and assign it.
-
To disqualify the competitor press <F2>. The disqualified time is marked with the prefix d. For
a disqualification it clears the start time, finish time, and run time.
-
Exit the menu by pressing <MENU> and <INPUT> of the finish keyboard (15) together.
Attention:
-
If it shows 00:00:00.000 as run time, it means that you have no run time for this
start number.
-
If you make another run time valid, it stores the old memory time with a c (clear).
E.g.: c 0009 MT 00:01:32.446
-
You can over write the valid intermediate time with the finish keyboard (15) (manual input ).
-
If you want to copy the selected time to another start number press <F1> and assign it.
-
Exit the menu by pressing <MENU> and <INPUT> of the finish keyboard (15) together.
Attention:
-
If it shows 00:00:00.000 as memory time, it means that you have no memory
time
for this start number.
-
If you make another intermediate time valid, it stores the old intermediate time
with a c (clear).
E.g.: c0009 C2 00:01:32.446