TdC 8000 for Equestrian
Page 67
Version: E-01-08-08
Page 67
Block Time 1:
Menu 41
Block Time 1 = 000.00
As long as the block time 1 is running, it will take every impulse of the finish photocell as a not valid
impulse during stage 1. This time will be printed only as time of day with a question mark. The time
will not be stopped on the display (7) or display board. Use the block time for events where the rider
passes the finish photocell before he reaches the finish.
Menu 41: BLOCK TIME 1 = 000.00
Input the block time
Save with:: ENTER
Save and exit with <ENTER>
Pre adjusted value::
no block time is pre adjusted!
Block Time 2:
Menu 42
Block Time 2 = 000.00
As long as the block time 2 is running, it will take every impulse of the finish photocell as a not valid
impulse during stage 2. This time will be printed only as time of day with a question mark. The time
will not be stopped on the display (7) or display board. Use the block time for events where the rider
passes the finish photocell before he reaches the finish.
Menu 42: BLOCK TIME 2 = 000.00
Input the block time
Save with:: ENTER
Save and exit with <ENTER>
Pre adjusted value::
no block time is pre adjusted!
Count Down Time 1: Menu 43
Count Down Time = 000060.00
You can adjust the count down time between 0 and 6399.99 seconds. The count down time is the
time between the greeting of the judges and the time when the rider must start. It is possible to
show the count down time on a display board (see menu 43). A horn (if connected) honks at the
start and end of the count down.
Menu 43: COUNT DOWN TIME 1 = 000060.00
Input count down time
AUTOMATIC START = EIN
Automaticstart ON or OFF
Save with:: ENTER
Save and exit with <ENTER>
Pre adjusted value::
Count Down Time = 60 seconds