Manual
ASC3
Page 25
2.3.12 Program P08
The countdown starts to automatically count a new interval after the zero tone. The allowed
start time is 3 seconds before or after the zero tone.
In this program you can set the start light and the horn from 10 seconds to – 5 seconds (alto-
gether 15 seconds). This allows shorter start intervals (shortest interval time is 15 sec.)
Sports
:
nordic skiing – cross country
Green/Black Banana Socket (4):
start input from external start trigger device (e.g. start-
gate, photocell)
Red/Black Banana Socket (5):
to connect a push button for setting countdown time
White Banana Socket (6):
output of start impulse (zero impulse)
Multiport:
remote control for bib and countdown/brightness
Countdown Intervals:
CD1 = 0:15 min
CD2 = 0:20 min
CD3 = 0:30 min
CD4 = 0:40 min
CD5 = 0:45 min
CD6 = 1:00 min
CD7 = 1:15 min
CD8 =:1:20 min
CD9 = 1:30 min
CD0 = Break
The table below shows the ASC3 at a 15 second interval:
Countdown Display (D)
Start
Light
Horn
10
10
Red
low
9
9
Red
off
8
8
Red
off
7
7
Red
off
6
6
Red
off
5
5
Red
low
4
4
Red
low
3
3
Green
low
2
2
Green
low
1
1
Green
low
0
0
Green
high
-1
14
Green
off
-2
13
Green
off
-3
12
Red
off
-4
11
Red
off
-5
10
Red
off
Summary of Contents for ASC3