2.3.8 Program P62
The countdown starts to count down from an adjustable interval time after pressing the push
button (externally connected to red/black banana socket (5)). The start light switches to
green when the countdown reaches zero. After the countdown reaching -10, no light and no
countdown time is displayed (only time of day).
If you press the external push button again during the countdown it stops the countdown and
shows the time of day only. If you press the external push button again it starts a new count-
down.
Sports
:
mass start with countdown for any sport
Green/Black Banana Socket (4):
start input from external start trigger device (e.g. start-
gate, photocell)
Red/Black Banana Socket (5):
to connect push button for activating start
White Banana Socket (6):
output of start impulse (zero impulse)
Multiport:
remote control for bib and countdown/brightness
standard: Bib = OFF
Countdown Intervals:
CD1 = 0:10 min
CD6 = 0:40 min
CD2 = 0:15 min
CD7 = 0:45 min
CD3 = 0:20 min
CD8 = 1:00 min
CD4 = 0:25 min
CD9 = 1:30 min
CD5 = 0:30 min
CD0 = Break
Countdown
Display
Start
Light
Horn
10
10
Red
low
9
9
Red
off
8
8
Red
off
7
7
Red
off
6
6
Red
off
5
5
Red
low
4
4
Red
low
3
3
Yellow
low
2
2
Yellow
low
1
1
Yellow
low
0
0
Green
high
-1
-1
Green
off
-2
-2
Green
off
-3
-3
Green
off
-4
-4
Green
off
-5
-5
Green
off
-6
-6
Green
off
-7
-7
Green
off
-8
-8
Green
off
-9
-9
Green
off
-10
-10
Red
off