ASDI Operations and Maintenance – TX Models – P/N: 52368
6-36
Full
Load
Current
Check
NOTE
See fusible link detail below for typical fusible link installation.
WARNING
These tests include high voltage. Exercise great caution in making
the following tests. Carelessness could result in severe injury or
death. See additional warnings located at the beginning of this
Chapter.
Measure the current on each of the heater AC power input wires.
See Data
Sheet or rating plate
provided with your manual for the correct reading (line
current) for your vaporizer. All wires should have readings equal to +/- 3% of the
value listed on the rating plate.
Low current on all wires indicates low input voltage. Drastically different current
readings may indicate a defective heater, defective wiring, or an open fusible link
due to overheating. If a fusible link is open, contact the factory. Do not attempt to
repair it.
Figure 13 – Full Load Current Check
VIEW OF FUSIBLE
LINKS IN OPEN
CONDITIONS
VIEW OF FUSIBLE
LINKS IN NORMAL
CONDITIONS
COPPER STRIP
MEASURE CURRENT
POWER
INPUT
WIRING
AMP CLAMP
CONTROL
BOARD
POWER IN
FUSIBLE LINKS
Summary of Contents for TORREXX TX100
Page 8: ......
Page 56: ...APPENDIX A TECHNICAL INFORMATION ...
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 83: ...ASCO Valve used by Algas SDI ...
Page 86: ...ASCO Valve used by Algas SDI ...
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ......