6-41
ASDI Operations and Maintenance – TX Models – P/N: 52368
Thermocouple
Sensor
Replacement
CAUTION
Always disconnect power to vaporizer before servicing.
1) Shut off power at the disconnect.
2) Remove the control box lid.
3) Disconnect the main power wires attached to the contactor and the wires
going to the heaters.
4) Slide the circuit panel half way out of the control box.
5) Disconnect the yellow and red thermocouple wires from control board.
6) The thermocouple can now be removed from the center of the core (see
Figure 18 and 19). Two types of locking collars have been used on the
sensors.
Figure 17 – TORREXX Box showing Thermocouple location
THERMOCOUPLE WIRES
Summary of Contents for TORREXX TX100
Page 8: ......
Page 56: ...APPENDIX A TECHNICAL INFORMATION ...
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 83: ...ASCO Valve used by Algas SDI ...
Page 86: ...ASCO Valve used by Algas SDI ...
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ......