ASDI Operations and Maintenance – TX Models – P/N: 52368
TREE # 2B
Liqui-SAFE VALVE DOES NOT TRIP
GREEN
IS CONTACTOR
LATCHED?
CHECK FUSE LINKS
FUSE LINKS
OPEN?
REPLACE OPEN
FUSE LINKS.
CONTACT ASDI
YES
NO
CHECK FOR LOOSE
WIRING
YES
NO
PRESS HI-LIMIT
BUTTON TO RESET
VAPORIZER
STARTS
WORKING?
CHECK:
1. IF THERMOCOUPLE
CONNECTION IS LOOSE.
2. IF THERMOCOUPLE IS BAD
3. CHECK FOR SUFFICIENT
THERMAL GREASE IN THE
THERMOWELL
4. REMOVE DRAIN PLUG AND
CHECK FOR HEAVY ENDS
IF THE ABOVE ACTIONS DO
NOT FIX THE PROBLEM THEN
REPLACE TEMPERATURE
CONTROLLER BOARD.
CHECK IF THERE
IS 24V AT THE
CONTACTOR
LEADING TO THE
TEMPERATURE
CONTROLLER
NO
YES
24V AT THE
CONTACTOR?
YES
NO
REPLACE
CONTACTOR
IS THERE A
LOOSE WIRE?
TIGHTEN WIRES.
RESTART
VAPORIZER.
SEE HEATER CORE
RESISTANCE ON
PAGE 6-37.
NO
YES