![AlfaRadio AlfaSpid MD-01 Manual Download Page 33](http://html1.mh-extra.com/html/alfaradio/alfaspid-md-01/alfaspid-md-01_manual_2895616033.webp)
Alfa Radio Ltd.
11211 - 154 St. Edmonton, Alberta, Canada T5M 1X8
0.5000 for BIG-RAK and BIG-RAS
5.3.6 MIN ANGLE
Limits the minimum angle to which the motor can turn. Default -180
5.3.7 MAX ANGLE
Limits the maximum angle to which the motor can turn. D180
5.3.8 MAX POWER
Maximum power, as a percentage of full power, that the controller can
provide to the rotator motor.
5.3.9 START POWER, START TIME
Used if you want to obtain a “soft-start”. You can set a one, two, or
three-stage motor start
(START POWER 1, START POWER 2, and START POWER 3)
Power is expressed as a percentage of full power.
(START TIME 1, START TIME 2 and START TIME 3)
START TIME is expressed in seconds.
Page 33 of 55 AlfaSpid_MD-01-02_12APR2022.odt
Copyright
Alfa Radio Ltd. 2022