The Elevation map is ignored when the MD-01/02 is controlling manually.
Note: MIN ANGLE and MAX ANGLE in SET MOTOR 1 (SET MOTOR 2) have a higher
priority than the angles of elevation map. The rotator will not go beyond
these limits.
5.2.4 Const EL MAP
If this option is set to ON, option USE EL. MAP is ignored, and a minimum
elevation angle of 0 degrees azimuth is set for all azimuth angles.
This option is ignored when MD-01 is controlling manually.
Note: MIN ANGLE and MAX ANGLE in SET MOTOR 1 (SET MOTOR 2) have a higher
priority than the angles of elevation map. The rotator will not go beyond
these limits.
5.2.5 Start
Motors run mode:
This is set for each motor separately in modules SET MOTOR 1 and SET MOTOR
2, as described later in section 5.3.9,
IMMEDIATELY - motor starts with max speed, soft start is not active.
SOFTLY – soft start is active (See 5.3.9 for details).
5.2.6 Stop
Motors stop mode:
This is set for each motor separately in modules SET MOTOR 1 and SET MOTOR
2, as described later in section 5.3.10,
IMMEDIATELY – at once, soft stop not active.
SOFTLY – soft stop is active (See 5.3.10 for details).
5.2.7 Mouse Control
If you have a specially designed mouse by SPID (RAS Mouse – section 2.5),
you can connect it to the MD-01 controller on OUT3 port (13 in back picture
of MD01/02). The mouse works if you set this option to ON.
5.2.8 External control (CONTROL xx)
This parameter specifies the communication port that is used to control the
connected motors. This parameter is not available when template 1: NC, 2: NC
is chosen.
Page 30 of 55 AlfaSpid_MD-01-02_12APR2022.odt
Copyright
Alfa Radio Ltd. 2022