background image

The device is of one piece with the thermal valve and valve for filling. 
Valve opening temperature is 100°C (+0°C/-5°C). 
The fluid recommended in the installation is water and glucose antifreeze of 30%. 
 

Note: 

At reaction, and valve operation, during fluid cooling in an overheated boiler part of the new fluid is injected into the boiler, 

but the part is also ejected from the boiler. It will be poured down the drain. If the antifreeze is in the installation you  must 
keep in mind that a certain percentage will go out and pour down the drain! 

We recommend the thermal valve Caleffi type 544, 1/2" as shown in Figure 7a. 
 

7.2.2.

 

SLOPE PRESSURE REGULATOR 1/2" WITH MANOMETER (Fig. 7, Item 19 and Fig. 7b) 

When  installing  the  thermal  valve  it  is  required  to  mount  the  slope  pressure  regulator  as  shown  in  Fig.  7,  Item  19.  The 

pressure  that  is maintained by pressure regulator must be set at a higher pressure than the pressure that is in the heating 
system. If you do not have a higher water pressure of at least 0.8 bar compared to the pressure in the heating system thermal 
valve will not work or cannot inject cold water into the boiler that needs to be cooled. 

Pressure regulator should be set to 2.8 to 3 bars. 
You should take into account the direction of placing the slope pressure regulator! 
 

7.2.3.

 

WATER FILTER OF THE BOILER INTAKE (Fig. 7, Item 20) 

In front of the slope pressure regulator on water intake from water supply line it is necessary to install a filter that will clean 

the  water  from  solid  objects,  primarily  of  sand,  which  can  damage the tap seal or seals of the thermal valve and the slope 
pressure regulator. 

This filter does not need to be resistant to high water temperatures due to cold water that flows through. 
 

7.2.4.

 

WATER FILTER OF THE BOILER OUTLET (Fig. 7, Item 21) 

It is required to install the filter on the boiler outlet which will clean the hot - boiling water from dirt and solid objects that 

can damage the tap seals, or seals of the thermal valve. 

This filter must be resistant to water temperatures up to 150°C. 
 

NOTES: 

- After the completion of thermal valve activation, checking the pressure in the installation and filling the system with cold 

water is mandatory. 

-  In  cases  where  antifreeze  is  used,  after  filling  the  installation  with  water  it  is  required  to  check  percentage  content of 

antifreeze in a mixture of water and antifreeze! 

 

7.3.

 

SAFETY VALVE (Fig. 7 and 8, Item 5 and Fig. 4, Item 6) 

An R1/2" connection (Fig. 4, Item 6) is welded at the back of the boiler, under the cooktop frame, on which  a safety valve 

MUST be fitted. The safety valve should be 2.5 to 3 bars. You can fit it directly on the connection or at a distance from the 
connection of at least 1 m, provided that there is no block valve between the boiler and the safety valve. 

In general, safety valve is not fitted in open circuits, but we advise you to fit it nonetheless, as another safety precaution for 

the boiler and the system (in case of emergency). 

NOTE: 
If the safety valve is not fitted as described above, the warranty will not be valid. 
 

7.4.

 

THERMOMETER AND PRESSURE GAUGE (Fig. 1, Items 16 and 17 and Fig. 5) 

Thermometer and pressure gauge are installed on the stove, on the additional lid (Fig. 1, Item 24) between the firebox door 

and the ash pan door (Fig. 1, Items 16 and 17, and Fig. 5) and therefore it is not necessary to install them. 

Thermometer, Item 17, shows the temperature of water in the boiler (operating temperature) in ºC. 
Pressure gauge, Item 16, shows the pressure of water in the boiler or the system in bars. 

 

 

 

 

Figure

 

 

 

 

 

 

Figure 6 

 

8.

 

PRACTICAL 

INSTRUCTIONS 

AND 

HEATING 

SYSTEM 

OPERATION ADVICE  

 

-

 

We recommend you to use a closed circuit, due to corrosion hazard related to open circuits.   

-

 

All connections must be well sealed and tightened. 

-

 

Before startup, the entire system needs to be tested with water under 2.4 bar pressure. 

-

 

It is recommended to discharge the water from the system at least once, to empty the system of dirt. 

Summary of Contents for ALFA TERM -27

Page 1: ...ALFA TERM 27 This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollution level in order to contribute to the reduction of energy consumption and negative en...

Page 2: ...eating power is shown for stoking dry beech wood with lower heating power Hd 4255W kg DEAR BUYERS Thank You for the trust you showed us buying our stove for floor heating We assure You that You have c...

Page 3: ...2 1 THERMAL VALVE WITH BUILT IN THERMAL PROTECTION Fig 7 Item 13 and Fig 7a 7 7 2 2 SLOPE PRESSURE REGULATOR 1 2 WITH MANOMETER Fig 7 Item 19 and Fig 7b 8 7 2 3 WATER FILTER OF THE BOILER INTAKE Fig...

Page 4: ...CKAGING MAY CAUSE SUFFOCATION THESE INCLUDE PLASTIC BAGS FILMS STYROFOAM ETC 2 3 THE RESPONSIBILITY OF THE INSTALLER The responsibility of the installer is to perform all the checkups of the flue pipi...

Page 5: ...Secondary air regulator knob 19 Ash pan door 10 Thermostat combustion regulator knob 12 Ash pan ash box 13 Grate holder 14 Wood box 15 Cleaning access plate 16 Pressure gauge 17 Thermometer 18 Cooktop...

Page 6: ...inet is mounted above the stove minimum clearance between the stove s cooktop and the cabinet should be at least 40 cm Combustible materials e g wallpapers door casings doors etc require a clearance t...

Page 7: ...box and screw it on the outlet on the cooktop or on the side outlet First remove the cover and use the same screws to fasten the collar NOTE If your chimney is of unsatisfactory or dubious quality we...

Page 8: ...is built on the outside walls it must be well insulated If the chimney connection is tightly connected to the chimney if the connection is extended If it is properly cleaned and free of birds nests di...

Page 9: ...ney pipes that have a rectangular internal cross section with a ratio that differs from the plan Modest efficiency 40 Chimney positioning and distance 7 INSTALLING THE STOVE IN THE WATER HEATING SYSTE...

Page 10: ...ssure regulator with manometer 1 2 the same or similar as shown in Fig 7b and Fig 7 Item 19 3 Filter for cold water at the input of the water supply to the thermal valve Fig 7 Item 20 4 Filter for hot...

Page 11: ...the hot boiling water from dirt and solid objects that can damage the tap seals or seals of the thermal valve This filter must be resistant to water temperatures up to 150 C NOTES After the completio...

Page 12: ...losed expansion vessel 7 Contact thermostat Note It is mandatory to install a thermal discharge valve with thermal protection the so called thermal fuse in accordance with the recommendations from the...

Page 13: ...ected to the chimney as described in the foregoing items NOTE The stove may not be used without water It must be connected to the system which is connected to consumers radiators with the power of no...

Page 14: ...d using the thermostat power regulator combustion regulator which is located in the ash pan door and which automatically sets the regulator damper depending on the regulation knob setting Fig 1 Items...

Page 15: ...odors the next time you heat the oven Clean the cooktop occasionally using fine sandpaper and in the event of longer breaks apply acid free oil on the cooktop vegetable oil Remove burnt material from...

Page 16: ...t If water is leaking from the valve replace the expansion vessel If only air comes out from the valve remove the installation vessel and pump it The pressure in the vessel must be equal to or greater...

Page 17: ...small number of radiators are switched on Transfer the grate to upper position or switch on some other radiator Keep the ashtray door closed 14 Water condensate in the boiler Damp heating material Cha...

Page 18: ...ate of undesirable objects 18 Outline dimensions of ALFA TERM 27 stove Figure 16 19 DETERMINING THE REQUIRED HEAT OUTPUT There is no absolute rule that would allow the calculation of the required heat...

Page 19: ...eating close the air inlet covers and DO NOT open the fireplace door Extinguish the fire with appropriate means home fire extinguisher NEVER USE WATER TO EXTINGUISH THE FIRE Also notify local firefigh...