2
0. TECHNICAL DATA
HEATING CAPACITY WITH THE GRATE IN DOWN POSITION:
Nominal heating capacity (wood)
27,56 kW
Heating capacity by radiation of heat (wood)
7,44 kW
Heating capacity to water (wood)
20,12 kW
HEATING CAPACITY WITH THE GRATE IN UP POSITION:
Nominal heating capacity (wood)
20 kW
Heating capacity by radiation of heat (wood)
6kW
Heating capacity to water (wood)
14,9 kW
REQUIRED CHIMNEY DRAFT
20 Pa
FLUE PIPE CONNECTION DIAMETER
150 mm
HEIGHT FROM THE FLOOR TO FLUE PIPE CONNECTION AXIS
690 mm
STOVE DIMENSIONS:
Width
900 mm
Height
850 mm
Depth
600 mm
OVEN DIMENSIONS:
Width
330 mm
Height
260 mm
Depth
440 mm
FIREBOX DIMENSIONS:
Width
315 mm
Height (min/max)
264/460 mm
Depth
414 mm
FIREBOX DOOR OPENING (width/height)
175/200 mm
FLOW AND RETURN PIPE CONNECTIONS
R1" RS
THERMO VALVE AND SAFETY VALVE CONNECTIONS
R1/2" RU
COOLING PIPE CONNECTIONS
R1/2" RS
BOILER VOLUME
25 l
HEATING VOLUME WITH THE GRATE IN DOWN POSITION:
340 – 450 m
3
(total)
Heating volume by radiation of heat
90 – 115 m
3
Hot water (radiator) heating volume
250 – 335 m
3
HEATING VOLUME WITH THE GRATE IN UP POSITION:
250 – 330 m
3
(total)
Heating volume by radiation of heat
75 – 100 m
3
Hot water (radiator) heating volume
175 – 230 m
3
MAXIMUM OPERATING PRESSURE
0.25 MPa
MAXIMUM OPERATING TEMPERATURE
90
C
WEIGHT (gross/net)
202/186 kg
Note:
The heating power is shown for stoking dry beech wood with lower heating power Hd=4255W/kg.
DEAR BUYERS!
Thank You for the trust you showed us buying our stove for floor heating. We assure You that You have chosen a quality
and economic product that is a result of many years of experience of this factory in the production of stoves and furnaces for
floor heating.
We hope that we fully met Your requirements in terms of design, as well as in terms of the surface of living area that you
can heat.
Please carefully read these instructions before connecting the stove and adhere to every advice provided herein.
-IT IS MANDATORY TO INSTALL A THERMAL DRAIN VALVE TOGETHER WITH THE THERMAL THERMAL PROTECTION OF
THE SO CALLED THERMAL FUSE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE USER'S MANUAL.
-IT IS MANDATORY TO INSTALL A CONTACT THERMOSTAT IN ORDER TO CONTROL THE CIRCULATION PUMP AT A
MINIMUM RECOMMENDED SET TEMPERATURE OF 57
ᵒ
C.
-IT IS MANDATORY TO USE FIREWOOD WITH A HUMIDITY PERCENTAGE OF LESS THAN 25% OR FIREWOOD THAT HAS
BEEN STORED IN A DRY OPEN SPACE FOR TWO YEARS
-THE MINIMUM INSTALLED POWER OF THE HEATING SYSTEM MUST NOT BE LESS THAN 65% OF THE NOMINAL POWER
OF THE STOVE AND THE MAXIMUM INSTALLED POWER OF THE HEATING SYSTEM MUST NOT BE MORE THAN 100% OF THE
NOMINAL POWER OF THE STOVE.
-THE CHIMNEY TO WHICH THE STOVE IS CONNECTED MUST MEET THE REQUIREMENTS PROVIDED IN THE USER
MANUAL.
-WHEN CONNECTING THE APPLIANCE TO THE CHIMNEY, NEVER USE FLEXIBLE HOSES INSTEAD OF FLUE PIPES.