background image

1.

 

PURPOSE 

 
Solid fuel stove for local heating is used for: 

-

 

cooking, 

-

 

baking, 

-

 

heating of apartments, houses and office premises, domestic hot water production. 

It is most often used as a stove for local heating, however, it can also be installed for central heating. 
This stove is intended for household use and may not be used for commercial purposes. 
 

2.

 

   

THE RESPONSIBILITY OF THE MANUFACTURER  

 

 

Upon publishing this Manual, ALFA PLAM will not accept any civil or legal responsibility, either direct on indirect, due to:  
− Accidents occurred due to the non-observance of the standards and specifications stated in this 
   Manual, 
 
− Accidents occurred due to the improper operation or use of the solid fuel by the user,  
− Accidents occurred due to any modifications and repairs not approved by ALFA PLAM, 
− Poor maintenance,  
− Unpredictable events,  
− Accidents occurred due to the use of spare parts that are not original spare parts or that are not  
   intended for these models of the solid fuel. 
 
The installer of the solid fuel shall take the full responsibility for the installation.  
 

2.1.

 

THE BASIC CHARACTERISTICS OF THE USER  

The solid fuel must be used by adult and responsible people.  
Make sure that children do not approach the solid fuel, when it is in use, with the intention of playing.  
Children must not approach the solid fuel, while in function, with the intention of playing. This appliance can be used by 

children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience 
and knowledge. if they are supervised by an elderly person who is familiar with the instructions of use. Children cannot carry 
out the cleaning and maintenance of the solid fuel, if they are not supervised by an elderly person. 

 

2.2.

 

THE TRANSPORTATION AND USE OF THE SOLID FUEL – HANDLING  

During the use of the solid fuel care should be taken that the solid fuel is not leaned forward because the centre of gravity 

of the solid fuel is oriented forward.   

While  moving  the  solid  fuel,  which  must  be  carried  out  absolutely  safely,  ensure  that  the  forklift  truck  has  a  carrying 

capacity that is higher than the weight of the solid fuel it should lift. Avoid twitches and abrupt movements.  

ALL  THE  PACKAGING  MATERIAL  SHOULD  BE  REMOVED  AWAY  FROM  THE  REACH  OF  CHILDREN  AS  THE  MATERIALS 

CONTAINED IN THE PACKAGING MAY CAUSE SUFFOCATION. THESE INCLUDE PLASTIC BAGS, FILMS, STYROFOAM, ETC.   

 

2.3.

 

THE RESPONSIBILITY OF THE INSTALLER 

The  responsibility  of  the  installer  is  to  perform  all  the  checkups  of  the  flue  piping,  air  intake/supply,  as  well  as  all  the 

solutions required for the installation (incorporation) of your solid fuel.  

The responsibility of the installer is to ensure that the solid fuel is in compliance with local regulations applicable in the 

place where the solid fuel is installed (incorporated).  

The use of the solid fuel must be in accordance with the instructions given in this Manual for use and maintenance, as well 

as with all the safety standards prescribed by local legal regulations applicable in the place where the solid fuel is installed 
(incorporated).  

The installer must verify (confirm):  
− The type of the solid fuel that is being installed,  
− Whether the room in which the solid fuel is being installed is appropriate, which is expressed as the minimum size of  
   the room required for the installation as prescribed by the solid fuel manufacturer,  
− Instructions of the heat generator manufacturer, related to the requirements of the smoke discharge system  
   (smoke discharge ducts and pipes),  
− The internal cross section of the chimney, material the chimney is made of, cross-sectional uniformity, whether  
   there are any obstacles and barriers in the chimney,  
− The height and vertical extension of the chimney,  
− The height above the sea level at the place of installation/incorporation,  
− The existence and suitability of a wind resistant protective cover of the chimney,  
− The possibility of providing the external air intake and the size of required openings,  
− The possibility of the simultaneous use of the solid fuel which is to be installed, together with the other equipment  
    already existing in that place.  
If the results of all the checkups are positive, then the installer may proceed with the incorporation/installation of the solid 

fuel. The instructions provided by the solid fuel manufacturer, as well as the fire prevention standards and safety standards 
must also be observed.   

When the installation is completed, the system must be put into a trial operation for at least 30 minutes in order to check 

up all the packing and seals of the system.  

When  the  incorporation  and  significant  details  are  completed,  the  installer  is  obliged  to  provide  the  client  with  the 

following:  

− The Use and Maintenance Manual issued by the solid fuel manufacturer (if such a manual has not been delivered  
   with the solid fuel),  

Summary of Contents for ALFA TERM -27

Page 1: ...ALFA TERM 27 This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollution level in order to contribute to the reduction of energy consumption and negative en...

Page 2: ...eating power is shown for stoking dry beech wood with lower heating power Hd 4255W kg DEAR BUYERS Thank You for the trust you showed us buying our stove for floor heating We assure You that You have c...

Page 3: ...2 1 THERMAL VALVE WITH BUILT IN THERMAL PROTECTION Fig 7 Item 13 and Fig 7a 7 7 2 2 SLOPE PRESSURE REGULATOR 1 2 WITH MANOMETER Fig 7 Item 19 and Fig 7b 8 7 2 3 WATER FILTER OF THE BOILER INTAKE Fig...

Page 4: ...CKAGING MAY CAUSE SUFFOCATION THESE INCLUDE PLASTIC BAGS FILMS STYROFOAM ETC 2 3 THE RESPONSIBILITY OF THE INSTALLER The responsibility of the installer is to perform all the checkups of the flue pipi...

Page 5: ...Secondary air regulator knob 19 Ash pan door 10 Thermostat combustion regulator knob 12 Ash pan ash box 13 Grate holder 14 Wood box 15 Cleaning access plate 16 Pressure gauge 17 Thermometer 18 Cooktop...

Page 6: ...inet is mounted above the stove minimum clearance between the stove s cooktop and the cabinet should be at least 40 cm Combustible materials e g wallpapers door casings doors etc require a clearance t...

Page 7: ...box and screw it on the outlet on the cooktop or on the side outlet First remove the cover and use the same screws to fasten the collar NOTE If your chimney is of unsatisfactory or dubious quality we...

Page 8: ...is built on the outside walls it must be well insulated If the chimney connection is tightly connected to the chimney if the connection is extended If it is properly cleaned and free of birds nests di...

Page 9: ...ney pipes that have a rectangular internal cross section with a ratio that differs from the plan Modest efficiency 40 Chimney positioning and distance 7 INSTALLING THE STOVE IN THE WATER HEATING SYSTE...

Page 10: ...ssure regulator with manometer 1 2 the same or similar as shown in Fig 7b and Fig 7 Item 19 3 Filter for cold water at the input of the water supply to the thermal valve Fig 7 Item 20 4 Filter for hot...

Page 11: ...the hot boiling water from dirt and solid objects that can damage the tap seals or seals of the thermal valve This filter must be resistant to water temperatures up to 150 C NOTES After the completio...

Page 12: ...losed expansion vessel 7 Contact thermostat Note It is mandatory to install a thermal discharge valve with thermal protection the so called thermal fuse in accordance with the recommendations from the...

Page 13: ...ected to the chimney as described in the foregoing items NOTE The stove may not be used without water It must be connected to the system which is connected to consumers radiators with the power of no...

Page 14: ...d using the thermostat power regulator combustion regulator which is located in the ash pan door and which automatically sets the regulator damper depending on the regulation knob setting Fig 1 Items...

Page 15: ...odors the next time you heat the oven Clean the cooktop occasionally using fine sandpaper and in the event of longer breaks apply acid free oil on the cooktop vegetable oil Remove burnt material from...

Page 16: ...t If water is leaking from the valve replace the expansion vessel If only air comes out from the valve remove the installation vessel and pump it The pressure in the vessel must be equal to or greater...

Page 17: ...small number of radiators are switched on Transfer the grate to upper position or switch on some other radiator Keep the ashtray door closed 14 Water condensate in the boiler Damp heating material Cha...

Page 18: ...ate of undesirable objects 18 Outline dimensions of ALFA TERM 27 stove Figure 16 19 DETERMINING THE REQUIRED HEAT OUTPUT There is no absolute rule that would allow the calculation of the required heat...

Page 19: ...eating close the air inlet covers and DO NOT open the fireplace door Extinguish the fire with appropriate means home fire extinguisher NEVER USE WATER TO EXTINGUISH THE FIRE Also notify local firefigh...