Use pursuant to applicable agreements
Cabling
....................................................................................................................................................................................................................................
Blue
Green/yellow
Brown
8 mm
(0.32 in)
3
Disassemble the cover assembly of the power connector. See the following figure:
Registration tab
Cover
30 mm screw
with gasket
}
Terminals
Nut
Top view of connector
with cover removed
Side view of connector
...................................................................................................................................................................................................
4
Feed the cable through the cable opening in the cover of the power connector and out
through the bottom of the cover.
...................................................................................................................................................................................................
5
Strip the cable according to the dimensions in the figure below. Assuming an H12 ground
position, the longest wire is the ground wire.
40 mm (1.6 in)