9500 MXC User Manual
3DB 23063 ADAA - Rev 004 July 2007
Vol. VI-B-17
• If there are no other alarms except downstream Demodulator Not Locked, and
path warning alarms, reboot (power-off, pause, power on).
• If other hardware alarms are present, check for a common cause, such as an
NCC power supply or process failure. Reboot, and if the alarms remain, replace
the NCC.
Additional Information
This alarm is only checked at power-on, reconfiguration, or software reload. Loss
of communications to the demodulator means its configuration cannot be loaded.
ADC Failure (ODU)
No communications with the analog to digital converter. This is a warning alarm.
Probable Cause
Equipment malfunction.
Recommended Actions
1.
Check for other alarms to determine how critical the failure is. Depending on
the malfunction, the Node/Terminal may otherwise operate satisfactorily.
2.
Reboot (power off, pause and power-on). If the alarm persists, replace the
ODU.
Additional Information
The ADC in the ODU is used to monitor voltages for presentation to the NCC/
IDU. A failure will affect RSL, Detected TX Power, and ODU voltage and
temperature readings.
RAC -48V Supply
RAC -48 volt supply out of tolerance. This is a warning alarm.
Probable Cause
Main 48 Vdc power supply to ODU is outside alarm limits of -40.5 to -60 Vdc.
Recommended Actions
1.
Check for other alarms to determine how critical the alarm is. In particular
check the NCC -48V alarm and the ODU -48V Supply alarm. Depending on
the malfunction, the link may otherwise operate satisfactorily.
2.
Check the -48V ODU supply voltage in the CT Performance screen. This, and
NCC and ODU -48 Vdc alarms indicate an out-of-tolerence -48 Vdc supply
Summary of Contents for 9500 MXC
Page 5: ......
Page 6: ......
Page 28: ......
Page 29: ...Volume I 9500 MXC Health and Safety Requirements...
Page 30: ......
Page 39: ...Volume II 9500 MXC System Description...
Page 40: ......
Page 56: ...Chapter 1 9500 MXC System Overview Vol II 1 16 Alcatel Lucent...
Page 94: ...Chapter 2 9500 MXC Terminals Vol II 2 38 Alcatel Lucent...
Page 218: ...Chapter 4 Outdoor Units Vol II 4 4 Alcatel Lucent...
Page 236: ...Chapter 6 9500 MXC Performance and Diagnostic Features Vol II 6 14 Alcatel Lucent...
Page 237: ...Volume III 9500 MXC Installation...
Page 238: ......
Page 268: ...Chapter 2 Outdoor Installations Vol III 2 26 Alcatel Lucent Figure 2 16 BGXZ Surge Suppressor...
Page 282: ...Chapter 2 Outdoor Installations Vol III 2 40 Alcatel Lucent...
Page 300: ...Chapter 4 Installing the IDU Vol III 4 6 Alcatel Lucent...
Page 321: ...Volume IV 9500 MXC CT...
Page 322: ......
Page 332: ...Chapter 1 9500 MXC CT Introduction Vol IV 1 10 Alcatel Lucent...
Page 362: ...Chapter 2 Setting Up 9500 MXC CT Vol IV 2 30 Alcatel Lucent...
Page 374: ...Chapter 3 Installation and Configuration Process Vol IV 3 12 Alcatel Lucent...
Page 384: ...Chapter 4 Licensing Vol IV 4 10 Alcatel Lucent...
Page 388: ......
Page 390: ......
Page 508: ...Chapter 8 Protection Vol IV 8 26 Alcatel Lucent...
Page 542: ...Chapter 10 Networking Configuration Vol IV 10 18 Alcatel Lucent...
Page 546: ......
Page 550: ...Chapter 12 Date and Time Configuration Vol IV 12 4 Alcatel Lucent...
Page 558: ...Chapter 13 Software Management Vol IV 13 8 Alcatel Lucent...
Page 562: ......
Page 632: ...Chapter 15 Diagnostics Vol IV 15 70 Alcatel Lucent Figure 15 27 Example Parts Screen...
Page 636: ...Chapter 15 Diagnostics Vol IV 15 74 Alcatel Lucent...
Page 637: ...Volume V Commissioning and Troubleshooting...
Page 638: ......
Page 699: ...Volume VI Appendices...
Page 700: ......
Page 791: ...9500 MXC User Manual 3DB 23063 ADAA Rev 004 July 2007 Vol VI B 65...
Page 792: ......
Page 826: ......
Page 846: ...Vol VI D 20 Alcatel Lucent...
Page 856: ...Vol VI E 10 Alcatel Lucent...
Page 873: ...9500 MXC User Manual 3DB 23063 ADAA Rev 004 July 2007 Vol VI F 17...
Page 874: ......