Cable Grounding
Ground kits are included in the ODU Cable Kits.
For tower/mast installations the ODU cable
must
be grounded at:
• The point where it comes on to the tower from the ODU
• The point where it leaves the tower to go to the equipment building
• Not more than 25 m (80 ft) intervals on the tower if the height on the tower
exceeds 50 m (165 ft)
• A point just prior to building entry. If the building-end lightning surge
suppressor is installed prior to the cable entering the building, the ground kit
must be installed on the tower side of the suppressor. Refer to Figure 2-18 on
page 2-28.
Figure 2-14 on page 2-22 shows typical tower locations for cable grounding and
lightning surge suppressors.Note that an external suppressor is shown at the
ODU end.
• An internal suppressor will be phased into production of ODU 300hp during
2007. An internal suppressor will not be installed in ODU 300ep. Refer to
Installing Lightning Surge Suppressors on page 2-23.
• For an ODU fitted with an internal surge suppressor, an ODU ground wire is
required.
At non-standard installations, such as building tops or the sides of buildings,
follow the same general guidelines but where proper grounding points are not
provided these must first be installed.
For ground kit installation instructions refer to the guide provided with each kit.
Summary of Contents for 9500 MXC
Page 5: ......
Page 6: ......
Page 28: ......
Page 29: ...Volume I 9500 MXC Health and Safety Requirements...
Page 30: ......
Page 39: ...Volume II 9500 MXC System Description...
Page 40: ......
Page 56: ...Chapter 1 9500 MXC System Overview Vol II 1 16 Alcatel Lucent...
Page 94: ...Chapter 2 9500 MXC Terminals Vol II 2 38 Alcatel Lucent...
Page 218: ...Chapter 4 Outdoor Units Vol II 4 4 Alcatel Lucent...
Page 236: ...Chapter 6 9500 MXC Performance and Diagnostic Features Vol II 6 14 Alcatel Lucent...
Page 237: ...Volume III 9500 MXC Installation...
Page 238: ......
Page 268: ...Chapter 2 Outdoor Installations Vol III 2 26 Alcatel Lucent Figure 2 16 BGXZ Surge Suppressor...
Page 282: ...Chapter 2 Outdoor Installations Vol III 2 40 Alcatel Lucent...
Page 300: ...Chapter 4 Installing the IDU Vol III 4 6 Alcatel Lucent...
Page 321: ...Volume IV 9500 MXC CT...
Page 322: ......
Page 332: ...Chapter 1 9500 MXC CT Introduction Vol IV 1 10 Alcatel Lucent...
Page 362: ...Chapter 2 Setting Up 9500 MXC CT Vol IV 2 30 Alcatel Lucent...
Page 374: ...Chapter 3 Installation and Configuration Process Vol IV 3 12 Alcatel Lucent...
Page 384: ...Chapter 4 Licensing Vol IV 4 10 Alcatel Lucent...
Page 388: ......
Page 390: ......
Page 508: ...Chapter 8 Protection Vol IV 8 26 Alcatel Lucent...
Page 542: ...Chapter 10 Networking Configuration Vol IV 10 18 Alcatel Lucent...
Page 546: ......
Page 550: ...Chapter 12 Date and Time Configuration Vol IV 12 4 Alcatel Lucent...
Page 558: ...Chapter 13 Software Management Vol IV 13 8 Alcatel Lucent...
Page 562: ......
Page 632: ...Chapter 15 Diagnostics Vol IV 15 70 Alcatel Lucent Figure 15 27 Example Parts Screen...
Page 636: ...Chapter 15 Diagnostics Vol IV 15 74 Alcatel Lucent...
Page 637: ...Volume V Commissioning and Troubleshooting...
Page 638: ......
Page 699: ...Volume VI Appendices...
Page 700: ......
Page 791: ...9500 MXC User Manual 3DB 23063 ADAA Rev 004 July 2007 Vol VI B 65...
Page 792: ......
Page 826: ......
Page 846: ...Vol VI D 20 Alcatel Lucent...
Page 856: ...Vol VI E 10 Alcatel Lucent...
Page 873: ...9500 MXC User Manual 3DB 23063 ADAA Rev 004 July 2007 Vol VI F 17...
Page 874: ......