9500 MXC User Manual
3DB 23063 ADAA - Rev 004 July 2007
Vol. III-4-3
Ventilation
IDUs have two redundant axial fans for cooling. IDUs must be located such
that unobstructed air passage is provide on each side for ventilation purposes.
A minimum of 50 mm (2”) of side spacing to any rack panels or cable bundles
should be provided for this purpose.
Maximum Ambient Temperature
The IDU is specified for a maximum ambient temperature (Tmra) of +45°
Celsius (113° Fahrenheit). The maximum ambient temperature (Tmra) of +45°
Celsius applies to the
immediate operating environment of the IDU
, which if
installed in a rack, is the ambient applying at its location within the rack.
Physical Stability
Ensure that adding an IDU to a rack does not adversely impact the physical
stability of the rack.
Power Supply
The IDU has the +ve pin on its dc power supply connector connected directly
to the chassis.
It must be used with a -48 Vdc power supply which has a +ve ground; the
power supply ground conductor is the +ve supply to the IDU.
There must be no switching or disconnecting devices in the ground conductor
between the dc power supply and the point of connection to an IDU.
Power Graphic
Power Supply Location
The IDU must be installed in the same premises as its dc power supply and be
located in the same immediate area (such as adjacent racks or cabinets) as any
other equipment that is connected to the same dc power supply.
Power Supply Compliance and
Loading
The dc power supply must be UL or IEC compliant for a -48 Vdc SELV output
(60 Vdc maximum).
Check to ensure that connection of a 9500 MXC system to an existing dc
supply does not overload the supply, circuit protection devices and wiring.
Where a new dc power supply is to be installed for an IDU, the power supply
must be rated to supply a minimum 5 A.
Grounding
The IDU must be grounded to the station or master ground, which must be the
same ground as used for the dc power supply. Normally this is achieved by
grounding the IDU to the ground bar in its equipment rack or frame. This bar
is most often located to one side of the rack or at rack top or bottom. In turn,
the ground bar is grounded to the station ground
Function / Requirement
Description
!
5A
This triangle graphic is located adjacent to the power connector
on the front panel to signify that the +ve pin on the connector
is directly connected to the chassis.
The number is the fuse rating in amps.
Summary of Contents for 9500 MXC
Page 5: ......
Page 6: ......
Page 28: ......
Page 29: ...Volume I 9500 MXC Health and Safety Requirements...
Page 30: ......
Page 39: ...Volume II 9500 MXC System Description...
Page 40: ......
Page 56: ...Chapter 1 9500 MXC System Overview Vol II 1 16 Alcatel Lucent...
Page 94: ...Chapter 2 9500 MXC Terminals Vol II 2 38 Alcatel Lucent...
Page 218: ...Chapter 4 Outdoor Units Vol II 4 4 Alcatel Lucent...
Page 236: ...Chapter 6 9500 MXC Performance and Diagnostic Features Vol II 6 14 Alcatel Lucent...
Page 237: ...Volume III 9500 MXC Installation...
Page 238: ......
Page 268: ...Chapter 2 Outdoor Installations Vol III 2 26 Alcatel Lucent Figure 2 16 BGXZ Surge Suppressor...
Page 282: ...Chapter 2 Outdoor Installations Vol III 2 40 Alcatel Lucent...
Page 300: ...Chapter 4 Installing the IDU Vol III 4 6 Alcatel Lucent...
Page 321: ...Volume IV 9500 MXC CT...
Page 322: ......
Page 332: ...Chapter 1 9500 MXC CT Introduction Vol IV 1 10 Alcatel Lucent...
Page 362: ...Chapter 2 Setting Up 9500 MXC CT Vol IV 2 30 Alcatel Lucent...
Page 374: ...Chapter 3 Installation and Configuration Process Vol IV 3 12 Alcatel Lucent...
Page 384: ...Chapter 4 Licensing Vol IV 4 10 Alcatel Lucent...
Page 388: ......
Page 390: ......
Page 508: ...Chapter 8 Protection Vol IV 8 26 Alcatel Lucent...
Page 542: ...Chapter 10 Networking Configuration Vol IV 10 18 Alcatel Lucent...
Page 546: ......
Page 550: ...Chapter 12 Date and Time Configuration Vol IV 12 4 Alcatel Lucent...
Page 558: ...Chapter 13 Software Management Vol IV 13 8 Alcatel Lucent...
Page 562: ......
Page 632: ...Chapter 15 Diagnostics Vol IV 15 70 Alcatel Lucent Figure 15 27 Example Parts Screen...
Page 636: ...Chapter 15 Diagnostics Vol IV 15 74 Alcatel Lucent...
Page 637: ...Volume V Commissioning and Troubleshooting...
Page 638: ......
Page 699: ...Volume VI Appendices...
Page 700: ......
Page 791: ...9500 MXC User Manual 3DB 23063 ADAA Rev 004 July 2007 Vol VI B 65...
Page 792: ......
Page 826: ......
Page 846: ...Vol VI D 20 Alcatel Lucent...
Page 856: ...Vol VI E 10 Alcatel Lucent...
Page 873: ...9500 MXC User Manual 3DB 23063 ADAA Rev 004 July 2007 Vol VI F 17...
Page 874: ......