Access the newly installed switch two ways:
•
•
C
ONSOLE
C
ONNECTION
To establish a console connection, you will need the following:
•
An ASCII terminal or a PC running terminal emulation software set to the parameters
shown in the table below.
•
A standard serial cable with a female DB9 connector.
For pinout information, refer to
Appendix C: Pinout Assignments on page 153
.
Table 30: Console Configuration Parameter Values
Parameter
Value
Baud Rate
115,200
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None