Field Replaceable Units
Page 134
7450 ESS-7
S
HUTTING
D
OWN
AND
M
ODIFYING
AN
IOM C
ONFIGURATION
NOTE
: IOMs and MDAs are hot swappable but you cannot replace an IOM without affecting the
MDA connectivity.
You can shut down ports, MDAs, and cards with the following commands in the
config
context:
Command
Example
Shut down ports:
Step 1
port
port-id
port 1/1/1
Step 2
s
hutdown
shutdown
Step 3
port
port-id
port 1/1/2
Step 4
s
hutdown
shutdown
Step 5
port
port-id
port 1/1/3
(etc.)
Step 6
s
hutdown
shutdown
Shut down the card:
Step 7
card
slot-number
card 1
Step 8
shutdown shutdown
Shut down the MDA(s):
Step 9
mda
slot-number
mda 1
Step 10
shutdown shutdown
Step 11
mda
slot-number
mda 2
Step 12
shutdown shutdown
Remove the MDA(s) and card from the configuration:
Step 13
card# no mda
slot-number
no mda 1
Step 14
card# no mda
slot-number
no mda 2
Step 15
config# no card
slot-number
no card 1
Summary of Contents for 7450 ESS-7