Field Replaceable Units
7450 ESS-7
Page 141
C
HANGING
THE
MDA C
ONFIGURATION
If you replace an MDA with a different type, you must change the configuration to reflect the new
MDA type prior to the installation. Each active port must be shut down in order to shut down and
remove an MDA configuration. Refer to the
Alcatel-Lucent OS System Guide
for details on
configuring cards, MDAs, and ports.
Issue the following commands in the
config
context to shut down ports and remove the MDA
from the configuration:
Command
Example
Step 1
port
port-id*
port 5/1/1
Step 2
shutdown
shutdown
*NOTE
: The
port>shutdown
command must be entered for all enabled ports on the MDA.
Step 3
exit
exit
Step 4
card
slot-number
card 5
Step 5
mda
mda-slot
mda 1
Step 6
shutdown
shutdown
Step 7
exit
exit
Step 8
no mda
mda-slot
no mda 1
Step 9
card
slot-number
card
5
Step 10
card-type
card-type
card-type iom-20g
Step 11
shutdown
shutdown
Step 12
mda
mda-slot
mda
1
Step 13
mda-type
mda-type
mda m1-10gb
Step 14
shutdown
shutdown
Step 15
exit
exit
Summary of Contents for 7450 ESS-7
Page 1: ...7450 ESS 7 INSTALLATION GUIDE February 2008 Document Part Number 93 0048 07 01 93 0048 07 01...
Page 6: ...Page 6 7450 ESS 7 Table of Contents...
Page 14: ...Preface Page 14 7450 ESS 7...
Page 28: ...Chassis Features Page 28 7450 ESS 7 Figure 6 7450 ESS 7 DC Power Entry Module SR70022...
Page 36: ...7450 ESS 7 System Installation Process Page 36 7450 ESS 7...
Page 108: ...Installing MDAs Page 108 7450 ESS 7...
Page 116: ...LEDs and Optics Page 116 7450 ESS 7...