For a proper operation, it’s required to set the time of day and date correctly. This is also necessary
for the automatic operation.
An outside temperature sensor must be installed / included to your system. Unless, the boiler
electronic controller (LMS 14) will accept the outside temperature as 0°C.
NoTE:
On the operating days, as a factory setting the weekend is already active. If you dont wish
an operation at weekend, you need to deactivate. For deactivation, first choose the Saturday to
Sunday via the parameter 500. Turn the wheel to the parameter 501 and make the line to “-----” and
also check the parameters from 502 to 506 if an active time exists. If exists, make all of them “---”.
4.3. Time Program Settings
Choose the “Time prog.heating circuit 1” under the engineer level. Then, choose the programme for
the heating circuit via the parameter 500.