background image

262673-UIM-B-0707

MODULAR
AIR HANDLERS

MODELS: MA - 115V

INSTALLATION MANUAL

ISO 9001

Certified Quality

Management System

SECTION I: GENERAL

This modular air handler provides the flexibility for installation in any
upflow, downflow, or horizontal application. These versatile models may
be used for cooling or heat pump operation with or without electric heat.

A BRAND LABEL (available from Distribution) may be applied to the
center of the blower access panel.

The unit can be positioned for bottom return air in the upflow position,
top return air in the downflow position, and right or left return in the hor-
izontal position.

Top and side power wiring and control wiring, accessible screw termi-
nals for control wiring and easy to install electric heaters all combine to
make the installation easy, and minimize installation cost.

SECTION II: SAFETY

This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.

Understand and pay particular attention to the signal words 

DANGER

,

WARNING

, or 

CAUTION

DANGER 

indicates an 

imminently

 hazardous situation, which, if not

avoided, 

will result in death or serious injury

.

WARNING 

indicates a 

potentially

 hazardous situation, which, if not

avoided, 

could result in death or serious injury

.

CAUTION 

indicates a potentially hazardous situation, which, if not

avoided 

may result in minor or moderate injury.

 It is also used to

alert against unsafe practices and hazards involving only property dam-
age.

Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer or service agency.

This product must be installed in strict compliance with the installa-
tion instructions and any applicable local, state, and national codes
including, but not limited to building, electrical, and mechanical
codes.

FIRE OR ELECTRICAL HAZARD
Failure to follow the safety warnings exactly could result in serious
injury, death or property damage.
A fire or electrical hazard may result causing property damage, per-
sonal injury or loss of life.

LIST OF SECTIONS

GENERAL  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
UNIT INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LOW VOLTAGE CONTROL CONNECTIONS   . . . . . . . . . . . . . . . . . . 5
REQUIRED CONTROL SET-UP  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

LINE POWER CONNECTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
BLOWER SPEED CONNECTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . .6
UNIT DATA   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

LIST OF FIGURES

Typical Installation with MC or FC Evaporator Coil   . . . . . . . . . . . . . . . 3
Coil and Air Handler Attachment Details  . . . . . . . . . . . . . . . . . . . . . . . 3
Dimensions & Duct Connection Dimensions  . . . . . . . . . . . . . . . . . . . . 4
Typical Horizontal Installation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Control Board  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Line Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Blower Speed Connections   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Control Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

LIST OF TABLES

Dimensions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Low Voltage Connections   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Fault Codes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Low Fan Control Inputs   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Blower Delays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Physical and Electrical Data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Electrical Data - Cooling Only (60 Hz)   . . . . . . . . . . . . . . . . . . . . . . . . .7
Air Flow Data - 60 Hz Models (115 Volt)   . . . . . . . . . . . . . . . . . . . . . . .7

Summary of Contents for MA - 115V

Page 1: ...rate injury It is also used to alert against unsafe practices and hazards involving only property dam age Improper installation may create a condition where the operation of the product could cause personal injury or property damage Improper installation adjustment alteration service or mainte nance can cause injury or property damage Refer to this manual for assistance or for additional informati...

Page 2: ...e who have not kept up with changing residential and non HUD modular home construction practices These instructions are required as a minimum for a safe installation INSPECTION As soon as a unit is received it should be inspected for possible dam age during transit If damage is evident the extent of the damage should be noted on the carrier s freight bill A separate request for inspection by the c...

Page 3: ...is document 8 Reposition and replace blower access panel AIR HANDLER AND COIL DOWNFLOW INSTRUCTIONS 1 Position blower casing over duct connection and secure such that the supply air end of the blower is down 2 Apply neoprene gasket to return air side of air handler 3 Place coil casing over blower return opening NOTE Tie plate and screws are provided with coils 4 Attach tie plate to casings of air ...

Page 4: ...al and or national codes This includes the standards of the National Fire Protection Association for Installation of Air Conditioning and Ventilat ing Systems NFPA No 90B AIR FILTERS Air filters and filter racks must be field supplied SUSPENSION KITS A suspension kit is available Models 1BH0601 unit size 018 060 is designed specifically for the units contained in this instruction upflow applicatio...

Page 5: ...s The humidity switch should be connected to the R and HUM terminals of the control See Figure 8 SECTION V REQUIRED CONTROL SET UP IMPORTANT The following steps must be taken at the time of installa tion to insure proper system operation 1 Consult system wiring diagram to determine proper thermostat wiring for your system 2 HEAT ENABLE jumper must be set to NO HEAT position 3 If a humidstat is ins...

Page 6: ... can be used to drive an external relay 24 VAC coil that switches the power input to the motor to a lower speed tap An accessory kit is available for this application The LOW FAN output is energized when the control has the following inputs as shown in Table 4 Blower Delays The control includes the following blower delays as shown in Table 5 SECTION VI LINE POWER CONNECTIONS Power may be brought i...

Page 7: ...1607 1533 1463 1395 1319 1044 851 725 673 673 Med 1308 1258 1197 1146 1097 887 742 648 608 609 Low 1148 1108 1061 1017 976 807 690 613 582 582 MC43B High 1462 1396 1322 1254 1172 1067 941 693 585 464 Med 1205 1154 1102 1046 980 897 704 560 441 220 Low 1075 1020 969 906 842 735 592 470 364 190 16C MC42C High 1959 1874 1802 1708 1606 1486 1408 1264 953 810 Med 1631 1587 1542 1473 1395 1315 1218 967 ...

Page 8: ... Control Board 4 MODE Jumper on AH control board should be set to A C for air conditioners and HP for heat pumps SECTION IX MAINTENANCE Filters must be cleaned or replaced when they become dirty Inspect at least once per month The frequency of cleaning depends upon the hours of operation and the local atmospheric conditions Clean filters keep unit efficiency high LUBRICATION The bearings of the bl...

Reviews: