23
IVR
EFB
ELECTRICAL ADJUSTMENT<MD>
All the MD blocks are adjusted and checked in the test mode.
If “No Adjust” is displayed, perform the adjustments of 1 to 3.
1. Temperature Compensation Adjustment
*
Normally, do not perform the temperature compensation adjustment.
If the adjustment value is extensively different, perform the adjustment as given below in a suitable environment for measuring
the correct temperature near the unit.
•
Test point: Check the test point on the display.
•
Tool: Thermometer
1)
After the MD test mode starts up, press the STOP button to display “ALL SV OFF”.
2)
Press the DISPLAY button to display “TEMP = $**”.
3)
Press the PAUSE button to display “T + **C: + 00”.
4)
Put the thermometer near the MD mechanism to measure the room temperature.
5)
Check the value of the thermometer and press the B.SKIP button and F.SKIP button to adjust until the value is the same as ** on
the display. Then press the ENTER button to store the value.
6)
After adjustment, press the STOP button to return the display to “ALL SV OFF”.
If “No Adjust” appears, perform 1) to 3) and press the ENTER button without changing the adjustment value with the B/F.SKIP
buttons.
2. Laser Power Adjustment
•
Test point: Check the test point on the display./Pickup laser output
•
Tool: Laser power meter (meters that can measure up to 10 mW)
2-1. Playback Laser Power Adjustment
1)
Press the MD EDIT button in the “ALL SV OFF” state to change the display to “LASER READ”.
2)
Press the PAUSE button once to display “LASER = $**”.
3)
Set it to “LASER = $11” using the B.SKIP and F.SKIP buttons, and press the ENTER button.
4)
Measure the pickup laser output using the laser power meter and adjust it using the B.SKIP button and F.SKIP button so that it is
around 0.68 mW.
5)
After adjustment, press the STOP button to change the display to “ALL SV OFF”.
2-2. Recording Laser Power Adjustment
1)
Press the MD EDIT button three times in the “ALL SV OFF” state to change the display to “LASER WRITE”.
2)
Press the PAUSE button once to display “LASER = $**”.
3)
Set it to “LASER = $9F” using the B.SKIP and F.SKIP buttons, and press the ENTER button.
4)
Measure the pickup laser output using the laser power meter and adjust it so that it is around 0.68 mW.
5)
After adjustment, press the STOP button to change the display to “ALL SV OFF”.
Note:
If the laser output exceeds 7.0 mW, the pickup may be damaged.
3. Automatic Sequence Adjustment (EFB/IVR/FOCUS AGC/TRACKING AGC adjustment)
•
Test point: Check the test point on the display.
•
Test disk: MDW-74, TGYS-1 or equivalent
3-1. Adjusting the MO Disk
1)
Load the MDW-74.
2)
Press the MD MODE button to display “SELECT GRV”.
3)
Press the MD function button to display “AUTO ADJ”. After adjustment, “DONE” is displayed. (If the adjustment failed,
“FAILED” appears.)
4)
Then, press the STOP button to return the display to “ALL SV OFF”.
3-2. IVR, EFB, Focus/ Tracking/ Sled Gain Check of MO Disk
1)
Move the pickup to the center of the disk using the B.SKIP button and F.SKIP button.
2)
Press the PLAY button to display “FOCUS ON!”.
3)
Press the ENTER button to display “ALL SV ON”.
4)
Press the STOP button and press the DISPLAY button twice.
Confirm that the values of “IV$**:EF$
⁄⁄
” are within the range shown below. (hexadecimal)
IV$ “**” .......... 03 to 07
EF$ “
⁄⁄
” ....... 09 to 12
Summary of Contents for XR-MD510
Page 5: ... 5 ...
Page 15: ... 15 SCHEMATIC DIAGRAM 1 MAIN PT1 PT2 RELAY ...
Page 17: ... 17 SCHEMATIC DIAGRAM 2 FRONT SW 1 SW 2 FACE A FACE B FACE C DECK ...
Page 20: ... 20 SCHEMATIC DIAGRAM 3 CD CD LOAD CD DRIVE ...
Page 22: ... 22 SCHEMATIC DIAGRAM 4 D TUNER ...
Page 24: ... 24 SCHEMATIC DIAGRAM 5 K TUNER ...
Page 26: ... 26 SCHEMATIC DIAGRAM 6 EZ TUNER ...
Page 29: ... 29 IC BLOCK DIAGRAM IC BA5936S IC BU2099FV ...
Page 30: ... 30 IC BU2092F IC BU1920FS ...
Page 31: ... 31 IC MM1454XFBE IC LA1837NL ...
Page 32: ... 32 IC TA2040AF IC HA12211 ...
Page 33: ... 33 IC CXA1553P IC LC72131D ...
Page 34: ... 34 IC BD3876KS2 ...
Page 38: ... 38 8 SFR130 TP3 VREF TP2 FE C CD C B L201 7 TP1 K SCAN GND IC201 7 B FRONT C B ...
Page 43: ... 43 98 O ARDY O 99 O SREQ O 100 I MREQ I ja ja 01234 ja 0123 fLl ...
Page 55: ... 55 FL 13 ST 44GNK ACJ 4 GRID ASSIGNMENT ANODE CONNECTION GRID ASSIGNMENT ...
Page 56: ... 56 ANODE CONNECTION ...