Product specification
6
General Information
Model Outdoor Unit
AWAU-YCZ327-H11(7SP091167)
Installation Method of Pipe
3 x AWSI-HND009-N11 3 x AWSI-HKD009-N11
Installation Method of Pipe
Flared
Flared
Characteristics
Units
Cooling
Heating
Cooling
Heating
Average
Average
Capacity
(1)
kW
7.8
8.5
7.8
8.5
Pdesign
kW
7.8
8
7.8
8
SEER / SCOP
(2)
W/W
6.6
3.9
6.1
3.8
Energy efficiency class
A++
A
A++
A
Annual energy consumption
kWh
414
2872
448
2947
Tbiv
o
C
N/A
-7
N/A
-7
Tol
o
C
N/A
-15
N/A
-15
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Circuit breaker rating
A
25
Rated power input (Maximum power input)
kW
3.6
Rated current (Maximum current)
A
16.5
O
UTDO
O
R
Refrigerant control
CaEXV
Compressor type. model
Twin Rotary DC Inverter
Fan type & quantity
Axial x 1
Fan speeds
H/L
RPM
800
Air flow
H/L
m3/hr
3500
Sound power level
(4)
H/L
dB(A)
68
Sound pressure level
(5)
H/L
dB(A)
58
Dimensions
WxHxD
mm
900x860x315
Weight
kg
62
Package dimensions
LxWxH
mm
1043x395x915
Packaged weight
kg
67
Stacking height
units
2 levels
Refrigerant type
R410A
Refrigerant charge (standard connecting tubing length) kg(10m)
2.4
Additional charge per 1 meter
gr / 1m
15m<L<45m 15g/m
Connections
between
units
Liquid line
In.(mm)
3x1/4”(Φ6.35)
Suction line
In.(mm)
3x3/8”(Φ9.52)
Max. length for all rooms
m
45
Max. length for one indoor unit
m
25
Max. height
difference
between
indoor and
outdoor unit
OU higher than IU
m
10
OU lower than IU
m
15
Max. height difference between indoor
units
m
10
Operation control type
Remote control
Summary of Contents for AWAU-YCZ218-H11
Page 24: ...Dimensions Outdoor Units 97 AWAU YCZ536 H11...
Page 29: ...Wiring Diagrams 102 Outdoor Units AWAU YCZ327 H11 7SP091167 AWAU YCZ327 H11 7SP091171...
Page 30: ...Wiring Diagrams Outdoor Units 103 AWAU YCZ430 H11 7SP091168 AWAU YCZ430 H11 7SP091172...
Page 31: ...Wiring Diagrams 104 Outdoor Units AWAU YCZ536 H11 7SP091169 AWAU YCZ542 H11 7SP091173...
Page 107: ...SERVICE MANUAL Multi Splits Series...