Table 29 – Accessories
Item
No.
Description
Manufacturer Manufacturer
P/N
Quantity Remark
1
Copper wire 0
AWG
N/A
N/A
N/A
Ground resistance must
be less than 1 Ohm.
UL approved cable
2
CAT-5e SFTP with
drain and double
jacket
N/A
N/A
N/A
Up to 100 meters
3
Bare Copper Wire
4/0 AWG
N/A
N/A
N/A
Ground resistance must
be less than 5 Ohm.
UL approved cable
Ring terminal
N/A
N/A
N/A
Stud H (1/4), Diameter
matching the used
Copper Wire diameter.
Circuit Lightning
protection for BSR
Polyphaser IX
series
IX-
2H1L1DC48-
IG
1
Installed with BSR
Circuit Lightning
protection for
ProST
Polyphaser IX
series
IX-2H1DC48-
IG
1
Installed with ProST
17.2 Cable Preparation (for grounding)
The CAT-5e SFTP cable is supplied unassembled. Therefore, you need to crimp the drain wire to
the ring terminal and paired wires to the connector's contact pins.
Required:
¾
CAT-5e SFTP cable
¾
Ring terminal and red insulation boot
¾
Crimping
tool
To crimp the CAT-5e SFTP “drain” wire to the ring terminal:
1. Carefully strip the insulation from the SFTP cable (5 – 10cm).
Caution:
Do not damage the insulation of the inner twisted pair wires.
2. Peel back the foil from around the wires.
3. Isolate the “drain” (ground) wire.
4. Crimp the ring terminal to the drain wire. Insert the wire into the ring terminal’s barrel, and
then, with a standard crimping tool crimp the barrel tightly onto the wire. Fold back the drain
wire with the ring terminal attached.
5. Strip the ends of the paired wires according to the connector.
6. Connect ground wire (with extension if required) to the tower.
The figures and connections are displayed below: