17 Lightning and Surge Protection
This section provides information for the installation of an effective grounding and suppression
system for the protection of products against lightning.
Different levels of protection should be decided jointly with customer according to:
¾
Geographical location / topographical conditions
¾
Environmental
conditions
¾
Required level of availability
•
Emergency Services
•
Commercial – based on SLA
•
Private use – based on SLA
¾
Cost factors
Level 1
¾
SFTP CAT-5e outdoor cable with proper grounding at both ends
Level 2
¾
SFTP CAT-5e outdoor cable proper grounding at both ends (Level 1)
¾
1 Lightning/Surge Protector on CAT-5e outdoor cable on BSDU/SDA end
Level 3
¾
SFTP CAT-5e outdoor cable proper grounding at both ends (Level 1)
¾
1 Lightning/Surge Protector on CAT-5e outdoor cable on BSDU/SDA end (Level 2)
¾
Additional Lightning/Surge Protector on BSR end
Table 27 - Level of Lightning Protection
Level of
Protection
Flash density * Equipment placement
**
Installation accessibility
***
Landscape
1
Low
Less than 50m
Good
Plane
2
Low
More than 50m
Good
Plane
3 Low
-
Poor
Plane
2
Medium
Less than 50m
Good
Plane
2
Medium
More than 50m
Good
Plane
3 Medium -
Poor
Plane
3 High -
-
Plane
1
Low
Less than 50m
Good
Hilly
2
Low
More than 50m
Good
Hilly
3 Low
-
Poor
Hilly
2
Medium
Less than 50m
Good
Hilly
2
Medium
More than 50m
Good
Hilly
3 Medium -
Poor
Hilly