16 Connecting BSDU to AC/DC Power converter
This section provides a description of how to connect the
Base Station Distribution Unit
(BSDU)
to the external
AC/DC Power
converter. This section explains the steps needed to connect the
two units together for proper functioning.
Table 26 - Required Equipment
Equipment Description
Part number
BSDU MMX-BSDU-1
AC/DC Converter
PC-BSDU-1
BSDU to AC/DC Converter Cable 68000110
BSDU to DC power Supply Cable supplied with BSDU kit
16.1 Connections
There are two sets of cables required for the BSDU and AC/DC converter to work properly.
¾
Cable with 25-pin D-type Male to 25-pin D-Type Male (part no. 68000110) with 2 cables
(UL 20AWG red color and UL 20AWG black color both with ring terminals).
Figure 57 - BSDU - AC/DC cable
Note:
This cable connects between the rear panels of the BSDU and the
AC/DC converter. It also has connections to the main DC Output of the
AC/DC converter, but the cable itself
DOES NOT
carry power to the BSDU.
These connections are used for sensing purposes, so that the PSU can