AirHarmony-1000 Installation Guide
UGD-D01006
Airspan Commercial and Internal Use
40
Figure 34: Power connection - on bottom panel of AirHarmony-1000
4. Screw the gland connector plug securely into the body cavity of the unit using the provided
Gland wrench.
5. Tighten the tail nut on to the body forcing the seal to compress around the power cable using
the (provided) Gland wrench.
Figure 35: Power cable assembly
Caution:
Do not over tighten the gland connector or the tail nut. The gland nut should be
tightened to a torque of no more than 3.3 Nm (2.43 lb-ft) max.
Note:
When securing the cable verify there is no tension on the connector so that it is
easy to disconnect and re-connect for future maintenance actions.
Caution:
The internal plastic parts of the mating connector are keyed. Take care to align
these by visual inspection or by gently rotating the connector body until the key way
sections align and the pins go in before tightening.
Figure 36: Power cable attached to AirHarmony-1000