![Airofog AE9 Series Instruction Manual Download Page 26](http://html1.mh-extra.com/html/airofog/ae9-series/ae9-series_instruction-manual_2878612026.webp)
25 AE: V2016-03
16. Fogging with EC:
- Engage the lever (EC13) and
lock its position by piston.
- For fogging, open the solution
tap (120), lever outwards.
- In order to stop fogging with
the EC engaged, close the
solution tap, lever inwards.
(Fig. 33)
17. Stop the Fogger
with EC:
1. To stop the fogger with EC,
firstly refer to para. 11
(Stopping the Fogger).
2. If the fogger stops unexpectedly
due to a lack of fuel or other
failure :
- EC is released automatically
and stops liquid flow.
- Close the solution tap (120)
completely (lever inwards) and
release pressure from the
solution tank by loosening tank
cap (2) immediately. Otherwise,
solution tank is still under
pressure and the solution can
get out when the lever is
activated by mistake.
(Fig. 34)
16. Vernebelung mit EC:
- Hebel (EC13) einrücken und
mit dem Kolbenstift fixieren.
- Zum Vernebeln den
Lösungshahn (120) öffnen
(Hebel nach herausziehen)
- Um die Vernebelung mit
eingerückter EC zu stoppen,
Lösungshahn schließen
(Hebel nach henein) (Abb. 33)
17. Stoppen des Nebelgeräts
mit der EC:
1. Zum Stoppen des Nebelgeräts
mit der EC zunächst Abschnitt
11, ”Stoppen des Nebelgeräts”,
lesen.
2. Wenn das Nebelgerät unerwartet
wegen Kraftstoffmangel oder
eines anderen Fehlers stoppt:
- EC wird automatisch
ausgerückt und stoppt den
Durchfluss der Flüssigkeit.
- Lösungshahn (120) vollständig
schließen (Hebel nach henein)
und Druck im Lösungsbehälter
durch sofortiges Lösen des
Tankdeckels (2) ablassen.
Anderenfalls steht der
Lösungsbehälter noch unter
Druck und die Lösung kann
austreten, wenn der Hebel
versehentlich eingerückt wird
(Abb. 34)
Fig.33
EC13
120
Open
Fig.34
120
EC13
2