Page 59
VERTICAL AIR FLOW EVAPORATOR COILS
.
AIRMAX INTAKE PLENUM/A
‐
COIL MODEL
50
‐
IPCE
‐
18A
1.0 Ton Split
‐
System Component Compatibility
①
Airmax ACU Condensing Unit Model
MAXAIR™ Air Handler Model
Cooling Indoor Airflow CFM
ACU
‐
12e
‐
1
30e (LV)
350
‐
425
1.5 Ton Split
‐
System Component Compatibility
①
Airmax ACU Condensing Unit Model
MAXAIR™ Air Handler Model
Cooling Indoor Airflow CFM
ACU
‐
18e
‐
1
50e (LV)
550
‐
650
2.0 Ton Split
‐
System Component Compatibility
①
Airmax ACU Condensing Unit Model
MAXAIR™ Air Handler Model
Cooling Indoor Airflow CFM
ACU
‐
24e
‐
1
50e (LV)
550
‐
650
Evaporator Coil Data
‐
Type
Face Area (sq.ft.)
Rows / F.P.I.
Refrigerant Control
Enhanced Plate Fin
3.10
2 / 18
TXV
Refrigerant
Connection Sizes
Liquid – ODS (inches)
Suction Gas – ODS (inches)
Condensate Drain (Primary and Secondary)
R
‐
410A
3/8
3/4
3/4 NPT
Plenum/Enclosure Dimensions
– H X W X D (in.)
Maximum Recommended R/A Opening Size (in.)
Minimum Recommended Filter Size (in.)
35.5 X 14.0 X 22.0
14.0 X 18.0
14 X 20 X 1
Shipping Weight (Lbs.)
45
1
Published performance achieved through the use of matched system components as indicated.
AIRMAX INTAKE PLENUM/A
‐
COIL MODEL
70
‐
IPCE
‐
24A
70
‐
IPCE
‐
30A
2.0 Ton Split
‐
System Component Compatibility
①
Airmax ACU Condensing Unit Model
MAXAIR™ Air Handler Model
Cooling Indoor Airflow CFM
ACU
‐
24e
‐
1
70e (LV)
750
‐
825
2.5 Ton Split
‐
System Component Compatibility
①
Airmax ACU Condensing Unit Model
MAXAIR™ Air Handler Model
Cooling Indoor Airflow CFM
ACU
‐
30e
‐
1
70e (LV)
930
‐
980
Evaporator Coil Data
‐
Type
Face Area (sq.ft.)
Rows / F.P.I.
Refrigerant Control
Enhanced Plate Fin
3.55
2 / 18
TXV
Enhanced Plate Fin
4.00
2 / 18
TXV
Refrigerant
Connection Sizes
Liquid – ODS (inches)
Suction Gas – ODS (inches)
Condensate Drain (Primary and Secondary)
R
‐
410A
3/8
3/4
3/4 NPT
Plenum/Enclosure Dimensions
– H X W X D (in.)
Maximum Recommended R/A Opening Size (in.)
Minimum Recommended Filter Size (in.)
43.5 X 18.0 X 22.0
18.0 X 18.0
20 X 20 X 1
Shipping Weight (Lbs.)
52
56
1
Published performance achieved through the use of matched system components as indicated.
Summary of Contents for MaxAir 100e P2
Page 43: ...Page 43 WIRING DIAGRAM P2 UNITS...
Page 44: ...Page 44 WIRING DIAGRAM P3 UNITS...
Page 45: ...Page 45 WIRING DIAGRAM P2 UNITS ALTERATIONS HEAT PUMP OPTION...
Page 46: ...Page 46 WIRING DIAGRAM P3 UNITS ALTERATIONS HEAT PUMP OPTION...
Page 51: ...Page 51 FAN COIL DIMENSIONS AND RETURN AIR SIZE LOCATION...
Page 52: ...Page 52...
Page 53: ...Page 53...
Page 54: ...Page 54...
Page 55: ...Page 55...
Page 56: ...Page 56...
Page 61: ...Page 61 2 AND 2 5 TON EVAPORATOR COIL SIZES 70 IPCE 24 30A...
Page 62: ...Page 62 SAMPLE PIPING SCHEMATICS...
Page 63: ...Page 63...
Page 64: ...Page 64...
Page 65: ...Page 65...