5
The installation must be performed by an authorised electrician and follow national standards and regulations.The in-
terlock device displayed on the diagram below is mandatory. A Typical example of the safety interlock would be to shut
down the main power to the generator when the exhaust fan is shutting down. An all-pole safety switch with a break
length of at least 3 mm must be installed as well. The electrical requirements for the ozone generator are 230V AC and
50 Hz. Each and every generator must be connected to its own 6A fuse.
Remove the four screws that fasten the AirMaid® alarm panel to it’s base. Fasten the base to the wall using devices
suitable for the wall material. In commercial kitchens place the alarm panel where it will be visable to the staff but
not to customers.
NOTE: Upon delivery the generator and alarm panel within the shipping carton are calibrated together and have
matching serial numbers. Make sure that generators are always connected to their own alarm panel.
If you desire to connect AirMaid® to an external monitoring or alarm system, you can accomplish this by connecting it to
the external alarm terminal block within the AirMaid® alarm panel.
NOTE: The maximum load is rated to 250V and 4A.
The earth ground cable is connected to the chassis screw next to the circuit board.
4 ELECRICAL CONNECTION AND SETTINGS
L
N
PE
230 VAC
MAX 6A
Plug & Play
ASSEMBLY AND ELECTRICAL INSTALLATION
EXTERNAL ALARM OUTLET
Connection to external
alarm device.
Voltage freerelay output
NO=Normally open
COM=Common
NC=Normally closed
Outlet power
connection
to generator
Inlet power
connection
from mains
AirMaid® Alarm Panel
Interlocking Device
All-pole Safety Switch
External Alarm Outlet
AirMaid® Ozone Generator
Performed by electrician
Plug & Play