background image

1. 

Check Product

2. 

System Overview 

3. 

Installation Guidelines

4.   Electrical connection and settings
5. 

System Test

6. 

Service and Maintenance

7. 

Technical Specification

8. 

Airmaid® Product Registration

Check that the shipment consists of the components below and that there is no visible damage. Any discrepancy must 

always be reported immediately to the distributor or manufacturer. Read through the complete guide before starting 

the installation.

1 x AirMaid® Ozone Generator 

 

 

1 x AirMaid® Alarm Panel

CONTENT

1 CHECK PRODUCT

LIMITED WARRANTY FOR INTERZON EQUIPMENT

This warranty is subject to the following conditions. 

A new product is warranted to be free from defects and workmanship for a period of 2 years. If the product regis-

tration form is submitted to Interzon within ten (10 days) from the completion of the installation, the guarantee 

will commence on this date.

A spare part is warranted to be free from defects and/or workmanship for a period of ninety (90) days from the 

date of the original installation.

The warranty for new equipment covers the repair or replacement of the defective part and includes labor 

charges according the recommended hours by Interzon and maximum kilometer charges of 300 km round trip.

The warranty for spare parts covers only the repair or replacement of the defective part and does not include any 

labor charges for the removal and installation of any parts, travel or other expenses incidental to the repair or 

replacement of a part.

Any claim must be presented to either Interzon or the distributor from whom the product was purchased. No 

allowance will be granted for repairs made by anyone else without Interzon written consent. If damage occurs 

during shipping, notify the sender at once so that a claim can be filed.

The above limited warranty does not apply to damage resulting from accident, alteration, misuse or if the serial 

number is removed or defaced.

2

This guide describes a typical installation in a commercial kitchen exhaust duct. The product can also be used 

in other applications as long as the specific requirements according to the guide are fulfilled.

The device may not be used by children or by persons with diminished physical, sensory or mental capacity 

or lack of experience and knowledge unless supervised or having received instruction. Supervise children to 

ensure that they do not play with the device.

Summary of Contents for AirMaid V

Page 1: ...Installation and service guide for AirMaid V ozone cleaning system 20 000 V AirMaid ozone cleaning system Innovative Air Treatment ...

Page 2: ...defective part and includes labor charges according the recommended hours by Interzon and maximum kilometer charges of 300 km round trip The warranty for spare parts covers only the repair or replacement of the defective part and does not include any labor charges for the removal and installation of any parts travel or other expenses incidental to the repair or replacement of a part Any claim must...

Page 3: ... order to reduce the frequency of filter changes the supply air should originate from a place containing the least possible impurities The tempera ture of supply air should not exceed 40 C AirMaid is very effective in reducing odors provided that the reaction time between the ozone and the exhaust air in the kitchen duct is at least 2 seconds This reaction time is important and must be taken into ...

Page 4: ...ct does not block any inspection holes Note that the direction of the airflow must correspond to the arrows on the generator and the picture below 3 Fasten the outlet tube 5 between the ozone generator and the kitchen duct 6 7 or the hood 8 Make sure that the connections are properly fixed and air tight 4 Connect the inlet tube 3 and the IRIS air damper 2 to the ozone generator 4 or use a filter b...

Page 5: ... customers NOTE Upon delivery the generator and alarm panel within the shipping carton are calibrated together and have matching serial numbers Make sure that generators are always connected to their own alarm panel If you desire to connect AirMaid to an external monitoring or alarm system you can accomplish this by connecting it to the external alarm terminal block within the AirMaid alarm panel ...

Page 6: ...f the generator according to the instructions found in this manual Call Service The RED lamp is flashing An error has lasted for more than 72 hours Contact the service company to remedy the error Press or to step through menu options or reposition the cursor Press or to change the value Press to select the current option Press for 5 seconds to save the displayed value To ENTER the settings menu Pr...

Page 7: ...ode will automat ically exit after one hour Set alarm delay By default the delay is set to 5 minutes in order to prevent an alarm in case of a temporary disruption Set inspect freq Service and maintenance interval in months Perform Recalibration This menu option must be used after the generator has been repaired and electronic components have been replaced Do not recalibrate at any other time EXIT...

Page 8: ... Ensure that the electrical wiring is correctly installed 3 Ensure that the exhaust fan is running 4 Ensure that the grease filters are properly installed in the hoods in the kitchen 5 Ensure that the main power switches are ON red light must glow at the ozone generators 6 Ensure that the interlock is working properly 7 Ensure that there is no leak in the tubing after the ozone generator 8 If the ...

Page 9: ...t the glass electrodes of the ozone cells are not damaged or cracked A proper ozone cell should be clean and free from any mechanical damage according to the picture to the right above 4 Clean the glass electrodes carefully with a soft towel together with some cleaning spirit Never use any sharp tools or abrasive materials for cleaning the glass electrodes 5 Close the service hatch and switch ON t...

Page 10: ...e end user wishes to discard this product it must be sent to separate collection facilities for recycling Facts about Ozone Ozone is a colorless gas with a pungent smell that can be detected by any person at a concentration of 0 02ppm 0 4mg m3 The smell of ozone is similar to chlorine like in a swimming baths Local protection legislations must be followed when using ozone In Sweden the Swedish Wor...

Page 11: ...ail Contact name Telephone E mail Product Serial No Date of installation mm dd yy Generator Airflow l s Generator Pressure Pa 8 AIRMAID Product Registration INSTALLATION SERVICE COMPANY Place of Installation PRODUCT IDENTIFICATION FROM SYSTEM TEST Interzon AB Phono 46 8 544 444 30 Propellervägen 4A Fax 46 8 544 444 39 SE 183 62 Täby Stockholm Email info interzon com Sweden Internet www interzon co...

Page 12: ...SE 183 62 Täby Stockholm Email info interzon com Sweden Internet www interzon com Reproduction modification or translation without a prior written consent is forbidden with the exception of what is permitted by the Act on Copyright Original instructions 2012 Copyright Interzon AB Edition 2 05 2013 ...