1. Overview
AirLive SI-104 User Manual
6
1.8 Tamper Switch Feature
If the Smoke Sensor is not mounted into the bracket properly, the tamper function is
triggered and the yellow LED is steadily on. You will hear temporal three sound with yellow
LED steadily on until Smoke Sensor is mounted back into bracket properly.
1.9 Battery Installation
If your controller receive low battery alarm and, this signal means that the Smoke Sensor's
battery is weak. When the device report the low battery message. The user should replace
the battery to new one to secure your protection. The battery type is CR123A, 3.0V.
The way to open the front cover please follow below steps.
1. Open battery compartment.
2.
Install battery into compartment and make sure the “+” and “-”ends of each battery are
aligned
properly.
3. After battery is installed in compartment, you will hear a chirp which indicates the device
is receiving battery power.
1.10 Choosing a Suitable Location
For complete coverage in residential units, Smoke Sensors should be installed in all rooms,
halls, storage areas, basements and attics in each family living unit. Minimum coverage is
one sensor on each floor and one in each sleeping area.
1. Install Smoke Sensor as close to the center of ceiling as possible. If this is not practical,
put the sensor on the ceiling, no closer than 4inches(10 cm) from any wall or corner.